{"id":14112,"date":"2025-10-12T16:01:06","date_gmt":"2025-10-12T16:01:06","guid":{"rendered":"https:\/\/qubyx.com\/outils-qubyx-os-maintenir-les-normes-dicom-de-maniere-transparente\/"},"modified":"2025-10-12T16:01:06","modified_gmt":"2025-10-12T16:01:06","slug":"outils-qubyx-os-maintenir-les-normes-dicom-de-maniere-transparente","status":"publish","type":"post","link":"https:\/\/qubyx.com\/fr\/outils-qubyx-os-maintenir-les-normes-dicom-de-maniere-transparente\/","title":{"rendered":"Outils QUBYX OS | Maintenir les normes DICOM de mani\u00e8re transparente"},"content":{"rendered":"<h2 style=\"text-align: center;\" data-start=\"0\" data-end=\"77\">Explication des outils QUBYX OS | La mani\u00e8re non intrusive de maintenir les normes DICOM<\/h2>\n<p>&nbsp;<\/p>\n<p data-start=\"79\" data-end=\"513\">Lorsque les d\u00e9cisions cliniques d\u00e9pendent des pixels, la calibration ne devrait pas perturber les soins, vous enfermer dans du mat\u00e9riel propri\u00e9taire ou n\u00e9cessiter une visite de service de type \u00ab white gant \u00bb \u00e0 chaque fois qu\u2019un seuil est franchi. <strong data-start=\"267\" data-end=\"285\">QUBYX OS Tools<\/strong> adopte une approche logicielle et non intrusive pour maintenir la conformit\u00e9 au <strong data-start=\"348\" data-end=\"370\">GSDF DICOM Part 14<\/strong> \u2014 afin que les \u00e9quipes de radiologie, mammographie, cardiologie et t\u00e9l\u00e9radiologie puissent maintenir les affichages conformes de mani\u00e8re continue, silencieuse et abordable.<\/p>\n<p data-start=\"515\" data-end=\"688\">Voici une pr\u00e9sentation pratique, au niveau de l\u2019ing\u00e9nierie, du fonctionnement des outils QUBYX OS, des raisons pour lesquelles le \u00ab non intrusif \u00bb est important, et de la mani\u00e8re de le d\u00e9ployer dans votre entreprise sans interruption.<\/p>\n<h2 data-start=\"695\" data-end=\"753\">Ce que signifie vraiment \u00ab non intrusif \u00bb en assurance qualit\u00e9 des \u00e9crans m\u00e9dicaux<\/h2>\n<p data-start=\"755\" data-end=\"860\"><strong data-start=\"755\" data-end=\"784\">La maintenance non intrusive<\/strong> consiste \u00e0 pr\u00e9server les flux de travail cliniques tout en assurant la conformit\u00e9 aux normes :<\/p>\n<ul data-start=\"862\" data-end=\"1268\">\n<li data-start=\"862\" data-end=\"949\">\n<p data-start=\"864\" data-end=\"949\"><strong data-start=\"864\" data-end=\"886\">Aucun engagement du fournisseur :<\/strong> Utilisez des moniteurs standards en plus des \u00e9crans m\u00e9dicaux.<\/p>\n<\/li>\n<li data-start=\"950\" data-end=\"1059\">\n<p data-start=\"952\" data-end=\"1059\"><strong data-start=\"952\" data-end=\"985\">Pas de r\u00e9accordage manuel constant :<\/strong> La calibration\/v\u00e9rification automatis\u00e9e s\u2019ex\u00e9cute selon le calendrier ou les d\u00e9clenchements de politique.<\/p>\n<\/li>\n<li data-start=\"1060\" data-end=\"1165\">\n<p data-start=\"1062\" data-end=\"1165\"><strong data-start=\"1062\" data-end=\"1089\">Aucune perturbation du flux de travail :<\/strong> Calibrez apr\u00e8s les heures de travail ou au d\u00e9but\/fin de la session sans interrompre les lectures.<\/p>\n<\/li>\n<li data-start=\"1166\" data-end=\"1268\">\n<p data-start=\"1168\" data-end=\"1268\"><strong data-start=\"1168\" data-end=\"1194\">Pas de bo\u00eetes noires opaques :<\/strong> Des profils et des traces d\u2019audit ouverts et respectueux des normes permettent d\u2019expliquer votre assurance qualit\u00e9.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1270\" data-end=\"1585\">En pratique, QUBYX OS Tools y parvient gr\u00e2ce <strong data-start=\"1317\" data-end=\"1391\">\u00e0 une calibration logicielle via des profils de liaison ICC et des LUT 3D int\u00e9gr\u00e9s<\/strong>, ainsi que des moteurs de v\u00e9rification align\u00e9s sur DICOM GSDF et directives associ\u00e9es (par exemple, AAPM TG18\/TG270 ; familles DIN 6868-157), ainsi que des rapports automatis\u00e9s adapt\u00e9s aux audits internes et aux contr\u00f4les r\u00e9glementaires.<\/p>\n<h2 data-start=\"1592\" data-end=\"1649\">  Comment QUBYX OS Tools maintient DICOM GSDF \u2014 Sous le capot<\/h2>\n<p>&nbsp;<\/p>\n<h3 data-start=\"1651\" data-end=\"1693\">1) Pipeline d\u2019\u00e9talonnage logiciel-d\u2019abord<\/h3>\n<ul data-start=\"1694\" data-end=\"2498\">\n<li data-start=\"1694\" data-end=\"1835\">\n<p data-start=\"1696\" data-end=\"1835\"><strong data-start=\"1696\" data-end=\"1713\">Entr\u00e9e du capteur :<\/strong> Fonctionne avec des colorim\u00e8tres\/spectros courants (lorsque disponibles) pour mesurer la r\u00e9ponse de luminance et la chromaticit\u00e9 de l\u2019\u00e9cran.<\/p>\n<\/li>\n<li data-start=\"1836\" data-end=\"2094\">\n<p data-start=\"1838\" data-end=\"2094\"><strong data-start=\"1838\" data-end=\"1867\">3D LUT + ICC liaison de dispositif :<\/strong> QUBYX OS Tools calcule une <strong data-start=\"1894\" data-end=\"1904\">LUT 3D<\/strong> et l\u2019empaquete \u00e0 l\u2019int\u00e9rieur d\u2019un <strong data-start=\"1931\" data-end=\"1958\">profil de liaison de dispositif ICC<\/strong>. Cela consolide des transformations complexes (r\u00e9ponse tonale, suivi en niveaux de gris, axe neutre, cartographie de gamut) en un seul fichier efficace. <\/p>\n<\/li>\n<li data-start=\"2095\" data-end=\"2314\">\n<p data-start=\"2097\" data-end=\"2314\"><strong data-start=\"2097\" data-end=\"2114\">Cartographie GSDF :<\/strong> Le niveau de gris est remapp\u00e9 dans la <strong data-start=\"2144\" data-end=\"2166\">GSDF de la Partie 14 de DICOM<\/strong> , de sorte que des pas \u00e9gaux en valeur des pixels correspondent \u00e0 des pas de luminance perceptuellement uniformes \u2014 essentiels pour une visibilit\u00e9 subtile du contraste dans les images de diagnostic.<\/p>\n<\/li>\n<li data-start=\"2315\" data-end=\"2498\">\n<p data-start=\"2317\" data-end=\"2498\"><strong data-start=\"2317\" data-end=\"2351\">Int\u00e9gration au niveau application :<\/strong> Le profil est appliqu\u00e9 au niveau du syst\u00e8me d\u2019exploitation\/pipeline graphique, garantissant la coh\u00e9rence entre les visualiseurs (PACS, 3D, protocoles suspendus) sans piratage par application.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2500\" data-end=\"2535\">2) V\u00e9rification et contr\u00f4le de la d\u00e9rive<\/h3>\n<ul data-start=\"2536\" data-end=\"3082\">\n<li data-start=\"2536\" data-end=\"2692\">\n<p data-start=\"2538\" data-end=\"2692\"><strong data-start=\"2538\" data-end=\"2559\">Contr\u00f4les programm\u00e9s :<\/strong> Des mod\u00e8les de test <strong data-start=\"2572\" data-end=\"2592\">l\u00e9gers de type TG18\/TG270<\/strong> et des contr\u00f4les de luminance ponctuels confirment que l\u2019affichage reste dans les tol\u00e9rances.<\/p>\n<\/li>\n<li data-start=\"2693\" data-end=\"2894\">\n<p data-start=\"2695\" data-end=\"2894\"><strong data-start=\"2695\" data-end=\"2715\">D\u00e9tection de d\u00e9rive :<\/strong> Si le delta par rapport \u00e0 la ligne de base d\u00e9passe vos seuils (par exemple, \u0394L\/L max, dEITP en niveaux de gris), le syst\u00e8me le signale et peut d\u00e9clencher un <strong data-start=\"2834\" data-end=\"2856\">recalibrage automatique<\/strong> lors de la prochaine fen\u00eatre de maintenance.<\/p>\n<\/li>\n<li data-start=\"2895\" data-end=\"3082\">\n<p data-start=\"2897\" data-end=\"3082\"><strong data-start=\"2897\" data-end=\"2934\">Compensation de la lumi\u00e8re ambiante (ALC) :<\/strong> Les lectures optionnelles ou les ajustements de politique compensent les changements d\u2019\u00e9clairage des pi\u00e8ces qui peuvent affecter le contraste per\u00e7u, en particulier dans les pi\u00e8ces polyvalentes.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"3084\" data-end=\"3115\">3) Reporting QA pr\u00eat pour l\u2019audit<\/h3>\n<ul data-start=\"3116\" data-end=\"3489\">\n<li data-start=\"3116\" data-end=\"3228\">\n<p data-start=\"3118\" data-end=\"3228\"><strong data-start=\"3118\" data-end=\"3142\">Historique par \u00e9cran :<\/strong> Stockez les dates d\u2019\u00e9talonnage, les instruments utilis\u00e9s, les tol\u00e9rances, les r\u00e9ussite\/\u00e9chec et les tendances de d\u00e9rive.<\/p>\n<\/li>\n<li data-start=\"3229\" data-end=\"3351\">\n<p data-start=\"3231\" data-end=\"3351\"><strong data-start=\"3231\" data-end=\"3254\">Rapports exportables :<\/strong> G\u00e9n\u00e9rez des PDF\/CSV pour la revue des physiciens, les audits d\u2019accr\u00e9ditation et les dossiers de maintenance des fournisseurs.<\/p>\n<\/li>\n<li data-start=\"3352\" data-end=\"3489\">\n<p data-start=\"3354\" data-end=\"3489\"><strong data-start=\"3354\" data-end=\"3375\">Tableaux de bord de flotte :<\/strong> Rep\u00e9rez les exceptions, les panneaux vieillissants et les pi\u00e8ces pr\u00e9sentant des probl\u00e8mes persistants de lumi\u00e8re ambiante \u2014 avant qu\u2019ils ne deviennent des probl\u00e8mes cliniques.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"3496\" data-end=\"3561\"><\/h2>\n<h2 data-start=\"3496\" data-end=\"3561\">Pourquoi le non-intrusif bat les approches traditionnelles \u00ab mat\u00e9rielles uniquement \u00bb<\/h2>\n<div class=\"_tableContainer_1rjym_1\">\n<div class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3563\" data-end=\"4149\">\n<thead data-start=\"3563\" data-end=\"3640\">\n<tr data-start=\"3563\" data-end=\"3640\">\n<th data-start=\"3563\" data-end=\"3575\" data-col-size=\"sm\">Crit\u00e8re<\/th>\n<p>\u00c9talonnage <\/p>\n<th data-start=\"3575\" data-end=\"3606\" data-col-size=\"sm\">centr\u00e9 sur le mat\u00e9riel<\/th>\n<th data-start=\"3606\" data-end=\"3640\" data-col-size=\"md\">Outils QUBYX OS (Non intrusifs)<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3655\" data-end=\"4149\">\n<tr data-start=\"3655\" data-end=\"3741\">\n<td data-start=\"3655\" data-end=\"3667\" data-col-size=\"sm\"><strong data-start=\"3657\" data-end=\"3666\">CapEx<\/strong><\/td>\n<td data-start=\"3667\" data-end=\"3695\" data-col-size=\"sm\">\u00c9lev\u00e9 (uniquement de qualit\u00e9 m\u00e9dicale)<\/td>\n<td data-start=\"3695\" data-end=\"3741\" data-col-size=\"md\">Moins (m\u00e9lange \u00e9conomique + qualit\u00e9 m\u00e9dicale)<\/td>\n<\/tr>\n<tr data-start=\"3742\" data-end=\"3832\">\n<td data-start=\"3742\" data-end=\"3756\" data-col-size=\"sm\"><strong data-start=\"3744\" data-end=\"3755\">Verrouillage<\/strong><\/td>\n<td data-start=\"3756\" data-end=\"3788\" data-col-size=\"sm\">Cartes\/sondes<\/td>\n<p> sp\u00e9cifiques au fournisseur<\/p>\n<td data-start=\"3788\" data-end=\"3832\" data-col-size=\"md\">Flux de travail ouverts ; ICC\/liaison de dispositif standard<\/td>\n<\/tr>\n<tr data-start=\"3833\" data-end=\"3916\">\n<td data-start=\"3833\" data-end=\"3848\" data-col-size=\"sm\"><strong data-start=\"3835\" data-end=\"3847\">Temps<\/strong><\/td>\n<p> mort<\/p>\n<td data-start=\"3848\" data-end=\"3882\" data-col-size=\"sm\">Cela n\u00e9cessite souvent des s\u00e9ances<\/td>\n<p> sur site<\/p>\n<td data-start=\"3882\" data-end=\"3916\" data-col-size=\"md\">Horaire, silencieux, apr\u00e8s les heures d\u2019ouverture<\/td>\n<\/tr>\n<tr data-start=\"3917\" data-end=\"3999\">\n<td data-start=\"3917\" data-end=\"3935\" data-col-size=\"sm\"><strong data-start=\"3919\" data-end=\"3934\">\u00c9volutivit\u00e9<\/strong><\/td>\n<td data-start=\"3935\" data-end=\"3963\" data-col-size=\"sm\">Complexe sur de nombreux sites<\/td>\n<td data-start=\"3963\" data-end=\"3999\" data-col-size=\"md\">Politiques centrales ; emplois automatis\u00e9s<\/td>\n<\/tr>\n<tr data-start=\"4000\" data-end=\"4069\">\n<td data-start=\"4000\" data-end=\"4019\" data-col-size=\"sm\"><strong data-start=\"4002\" data-end=\"4018\">Auditabilit\u00e9<\/strong><\/td>\n<td data-start=\"4019\" data-end=\"4038\" data-col-size=\"sm\">Journaux<\/td>\n<p> propri\u00e9taires<\/p>\n<td data-start=\"4038\" data-end=\"4069\" data-col-size=\"md\">Historique de la QA ouverte et exportable<\/td>\n<\/tr>\n<tr data-start=\"4070\" data-end=\"4149\">\n<td data-start=\"4070\" data-end=\"4088\" data-col-size=\"sm\"><strong data-start=\"4072\" data-end=\"4087\">Flexibilit\u00e9<\/strong><\/td>\n<td data-start=\"4088\" data-end=\"4111\" data-col-size=\"sm\">Cross-vendors<\/td>\n<p> limit\u00e9s<\/p>\n<td data-start=\"4111\" data-end=\"4149\" data-col-size=\"md\">Fonctionne sur diff\u00e9rents \u00e9crans\/GPU<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"4151\" data-end=\"4274\"><strong data-start=\"4151\" data-end=\"4167\">Conclusion:<\/strong> Vous maintenez la conformit\u00e9 DICOM GSDF tout en \u00e9largissant les options mat\u00e9rielles et en r\u00e9duisant le co\u00fbt total de possession.<\/p>\n<h2 data-start=\"4281\" data-end=\"4324\"><\/h2>\n<h2 data-start=\"4281\" data-end=\"4324\">O\u00f9 cela s\u2019inscrit : sc\u00e9narios cliniques courants<\/h2>\n<h3 data-start=\"4326\" data-end=\"4361\">Salles de lecture de radiologie primaire<\/h3>\n<ul data-start=\"4362\" data-end=\"4592\">\n<li data-start=\"4362\" data-end=\"4452\">\n<p data-start=\"4364\" data-end=\"4452\"><strong data-start=\"4364\" data-end=\"4373\">Besoin :<\/strong> GSDF constant, niveaux de noirs stables, contraste fiable pour des r\u00e9sultats subtils.<\/p>\n<\/li>\n<li data-start=\"4453\" data-end=\"4592\">\n<p data-start=\"4455\" data-end=\"4592\"><strong data-start=\"4455\" data-end=\"4468\">Approche :<\/strong> Plannings au niveau de la flotte (v\u00e9rification hebdomadaire ; calibration trimestrielle), avec fen\u00eatres adaptatives pour \u00e9viter d\u2019interrompre les charges de listes.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"4594\" data-end=\"4616\">Suites de mammographie<\/h3>\n<ul data-start=\"4617\" data-end=\"4828\">\n<li data-start=\"4617\" data-end=\"4707\">\n<p data-start=\"4619\" data-end=\"4707\"><strong data-start=\"4619\" data-end=\"4628\">Besoin :<\/strong> Tol\u00e9rances plus strictes, contr\u00f4les d\u2019uniformit\u00e9, stabilit\u00e9 de luminance \u00e0 plus haut cd\/m\u00b2.<\/p>\n<\/li>\n<li data-start=\"4708\" data-end=\"4828\">\n<p data-start=\"4710\" data-end=\"4828\"><strong data-start=\"4710\" data-end=\"4723\">Approche :<\/strong> Seuils plus stricts, v\u00e9rifications plus fr\u00e9quentes, et escalade plus rapide vers le recalibrage si un \u00e9cart appara\u00eet.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"4830\" data-end=\"4856\">T\u00e9l\u00e9commande et t\u00e9l\u00e9radiologie<\/h3>\n<ul data-start=\"4857\" data-end=\"5047\">\n<li data-start=\"4857\" data-end=\"4923\">\n<p data-start=\"4859\" data-end=\"4923\"><strong data-start=\"4859\" data-end=\"4868\">Besoin :<\/strong> Contr\u00f4le qualit\u00e9 sur divers postes de travail \u00e0 distance.<\/p>\n<\/li>\n<li data-start=\"4924\" data-end=\"5047\">\n<p data-start=\"4926\" data-end=\"5047\"><strong data-start=\"4926\" data-end=\"4939\">Approche :<\/strong> Des contr\u00f4les ax\u00e9s sur les politiques ; t\u00e9l\u00e9chargements s\u00e9curis\u00e9s de rapports \u00e0 distance ; Lib\u00e9rez les barri\u00e8res de conformit\u00e9 avant d\u2019autoriser les consultations cliniques.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"5049\" data-end=\"5085\">Affichages chirurgicaux\/interventionnels<\/h3>\n<ul data-start=\"5086\" data-end=\"5257\">\n<li data-start=\"5086\" data-end=\"5160\">\n<p data-start=\"5088\" data-end=\"5160\"><strong data-start=\"5088\" data-end=\"5097\">Besoin :<\/strong> R\u00e9ponse tonale pr\u00e9visible dans des conditions ambiantes plus lumineuses.<\/p>\n<\/li>\n<li data-start=\"5161\" data-end=\"5257\">\n<p data-start=\"5163\" data-end=\"5257\"><strong data-start=\"5163\" data-end=\"5176\">Approche :<\/strong> Profils avec contraintes conscientes de l\u2019ambiance et v\u00e9rifications planifi\u00e9es pendant les temps d\u2019arr\u00eat de la salle d\u2019op\u00e9ration.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"5264\" data-end=\"5296\">Sch\u00e9mas de d\u00e9ploiement qui fonctionnent<\/h2>\n<ol data-start=\"5298\" data-end=\"6175\">\n<li data-start=\"5298\" data-end=\"5534\">\n<p data-start=\"5301\" data-end=\"5324\"><strong data-start=\"5301\" data-end=\"5322\">Pilote (2 \u00e0 4 semaines)<\/strong><\/p>\n<ul data-start=\"5328\" data-end=\"5534\">\n<li data-start=\"5328\" data-end=\"5383\">\n<p data-start=\"5330\" data-end=\"5383\">S\u00e9lectionnez du mat\u00e9riel mixte (m\u00e9dical + commercial).<\/p>\n<\/li>\n<li data-start=\"5387\" data-end=\"5441\">\n<p data-start=\"5389\" data-end=\"5441\">\u00c9tablir des mesures de base et des profils GSDF.<\/p>\n<\/li>\n<li data-start=\"5445\" data-end=\"5534\">\n<p data-start=\"5447\" data-end=\"5534\">Validez la coh\u00e9rence du visionneur (PACS, 3D, MPR, protocoles suspendus) avec les champions cliniques.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"5536\" data-end=\"5785\">\n<p data-start=\"5539\" data-end=\"5562\"><strong data-start=\"5539\" data-end=\"5560\">D\u00e9finition de la politique<\/strong><\/p>\n<ul data-start=\"5566\" data-end=\"5785\">\n<li data-start=\"5566\" data-end=\"5643\">\n<p data-start=\"5568\" data-end=\"5643\">Fixez <strong data-start=\"5572\" data-end=\"5596\">des seuils de r\u00e9ussite\/\u00e9chec<\/strong> (par exemple, la d\u00e9viation maximale autoris\u00e9e par rapport \u00e0 la GSDF).<\/p>\n<\/li>\n<li data-start=\"5647\" data-end=\"5716\">\n<p data-start=\"5649\" data-end=\"5716\">D\u00e9finissez <strong data-start=\"5656\" data-end=\"5669\">les plannings<\/strong> (cadence de v\u00e9rification, fen\u00eatres d\u2019\u00e9talonnage).<\/p>\n<\/li>\n<li data-start=\"5720\" data-end=\"5785\">\n<p data-start=\"5722\" data-end=\"5785\">Choisissez <strong data-start=\"5729\" data-end=\"5755\">les destinations de rapport<\/strong> (local + d\u00e9p\u00f4t central).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"5787\" data-end=\"5931\">\n<p data-start=\"5790\" data-end=\"5812\"><strong data-start=\"5790\" data-end=\"5810\">D\u00e9ploiement en vagues<\/strong><\/p>\n<ul data-start=\"5816\" data-end=\"5931\">\n<li data-start=\"5816\" data-end=\"5870\">\n<p data-start=\"5818\" data-end=\"5870\">Priorisez les chambres \u00e0 haut risque (mammo, lectures primaires).<\/p>\n<\/li>\n<li data-start=\"5874\" data-end=\"5931\">\n<p data-start=\"5876\" data-end=\"5931\">Puis \u00e9tendez-vous aux cliniques satellites et aux points de service Telerad.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"5933\" data-end=\"6175\">\n<p data-start=\"5936\" data-end=\"5959\"><strong data-start=\"5936\" data-end=\"5957\">Exploiter et am\u00e9liorer<\/strong><\/p>\n<ul data-start=\"5963\" data-end=\"6175\">\n<li data-start=\"5963\" data-end=\"6019\">\n<p data-start=\"5965\" data-end=\"6019\">Surveillez les tableaux de bord pour d\u00e9tecter les probl\u00e8mes de d\u00e9rive et d\u2019environnement.<\/p>\n<\/li>\n<li data-start=\"6023\" data-end=\"6107\">\n<p data-start=\"6025\" data-end=\"6107\">It\u00e9rer les seuils par modalit\u00e9 (mammo, CT vs. IRM) et par cours d\u2019\u00e9clairage de la salle.<\/p>\n<\/li>\n<li data-start=\"6111\" data-end=\"6175\">\n<p data-start=\"6113\" data-end=\"6175\"><strong data-start=\"6122\" data-end=\"6137\">Des contr\u00f4les p\u00e9riodiques par<\/strong> un physicien\/responsable QA pour \u00eatre s\u00fbr.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2 data-start=\"6182\" data-end=\"6231\">\u00c9tape par \u00e9tape : un flux de travail typique non intrusif<\/h2>\n<ol data-start=\"6233\" data-end=\"7064\">\n<li data-start=\"6233\" data-end=\"6352\">\n<p data-start=\"6236\" data-end=\"6258\"><strong data-start=\"6236\" data-end=\"6256\">Mesurer la r\u00e9f\u00e9rence<\/strong><\/p>\n<ul data-start=\"6262\" data-end=\"6352\">\n<li data-start=\"6262\" data-end=\"6352\">\n<p data-start=\"6264\" data-end=\"6352\">Fixez le capteur, effectuez un balayage rapide de mesure (r\u00e9ponse luminance, suivi en niveaux de gris).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6353\" data-end=\"6523\">\n<p data-start=\"6356\" data-end=\"6378\"><strong data-start=\"6356\" data-end=\"6376\">G\u00e9n\u00e9rer un profil<\/strong><\/p>\n<ul data-start=\"6382\" data-end=\"6523\">\n<li data-start=\"6382\" data-end=\"6523\">\n<p data-start=\"6384\" data-end=\"6523\">Cr\u00e9ez un ICC liaison de dispositif avec une <strong data-start=\"6421\" data-end=\"6431\">LUT<\/strong> 3D int\u00e9gr\u00e9e ciblant DICOM GSDF et votre point de consigne de luminance (par exemple, 400 cd\/m\u00b2 pour mammo, selon la politique).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6524\" data-end=\"6652\">\n<p data-start=\"6527\" data-end=\"6550\"><strong data-start=\"6527\" data-end=\"6548\">Appliquer \u00e0 l\u2019\u00e9chelle du syst\u00e8me<\/strong><\/p>\n<ul data-start=\"6554\" data-end=\"6652\">\n<li data-start=\"6554\" data-end=\"6652\">\n<p data-start=\"6556\" data-end=\"6652\">Activez le profil au niveau du syst\u00e8me d\u2019exploitation\/graphisme ; V\u00e9rifie que le visualiseur PACS voit le pipeline corrig\u00e9.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6653\" data-end=\"6732\">\n<p data-start=\"6656\" data-end=\"6668\"><strong data-start=\"6656\" data-end=\"6666\">V\u00e9rifier<\/strong><\/p>\n<ul data-start=\"6672\" data-end=\"6732\">\n<li data-start=\"6672\" data-end=\"6732\">\n<p data-start=\"6674\" data-end=\"6732\">Effectuez une v\u00e9rification de type TG18\/TG270 pour enregistrer le passage initial.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6733\" data-end=\"6838\">\n<p data-start=\"6736\" data-end=\"6750\"><strong data-start=\"6736\" data-end=\"6748\">Calendrier<\/strong><\/p>\n<ul data-start=\"6754\" data-end=\"6838\">\n<li data-start=\"6754\" data-end=\"6838\">\n<p data-start=\"6756\" data-end=\"6838\">Configurez la v\u00e9rification hebdomadaire et l\u2019\u00e9talonnage trimestriel (ou selon la politique).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6839\" data-end=\"6925\">\n<p data-start=\"6842\" data-end=\"6854\"><strong data-start=\"6842\" data-end=\"6852\">Rapport<\/strong><\/p>\n<ul data-start=\"6858\" data-end=\"6925\">\n<li data-start=\"6858\" data-end=\"6925\">\n<p data-start=\"6860\" data-end=\"6925\">Exportez et classez le PDF\/CSV ; Activez la visibilit\u00e9 du tableau de bord de la flotte.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6926\" data-end=\"7064\">\n<p data-start=\"6929\" data-end=\"6952\"><strong data-start=\"6929\" data-end=\"6950\">Maintenez en silence<\/strong><\/p>\n<ul data-start=\"6956\" data-end=\"7064\">\n<li data-start=\"6956\" data-end=\"7064\">\n<p data-start=\"6958\" data-end=\"7064\">Laisser le planificateur rev\u00e9rifier et n\u2019alerter qu\u2019en cas de d\u00e9rive ; se recalibre automatiquement pendant les fen\u00eatres de maintenance.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2 data-start=\"7071\" data-end=\"7100\">Conseils de r\u00e9glage sur le terrain<\/h2>\n<ul data-start=\"7102\" data-end=\"7826\">\n<li data-start=\"7102\" data-end=\"7228\">\n<p data-start=\"7104\" data-end=\"7228\"><strong data-start=\"7104\" data-end=\"7144\">Choisissez des points de consigne de luminance r\u00e9alistes<\/strong> en fonction de la classe de la pi\u00e8ce ; Des cibles trop brillantes peuvent acc\u00e9l\u00e9rer l\u2019usure du r\u00e9tro\u00e9clairage et le d\u00e9rapage.<\/p>\n<\/li>\n<li data-start=\"7229\" data-end=\"7338\">\n<p data-start=\"7231\" data-end=\"7338\"><strong data-start=\"7231\" data-end=\"7262\">Stabiliser le comportement d\u2019\u00e9chauffement :<\/strong> Fixez un court arr\u00eat d\u2019\u00e9chauffement avant la mesure \u2014 surtout pour les panneaux plus anciens.<\/p>\n<\/li>\n<li data-start=\"7339\" data-end=\"7446\">\n<p data-start=\"7341\" data-end=\"7446\"><strong data-start=\"7341\" data-end=\"7365\">Standardisez les capteurs :<\/strong> Si possible, utilisez le m\u00eame mod\u00e8le de sonde sur plusieurs sites pour une uniformit\u00e9 des lectures.<\/p>\n<\/li>\n<li data-start=\"7447\" data-end=\"7567\">\n<p data-start=\"7449\" data-end=\"7567\"><strong data-start=\"7449\" data-end=\"7475\">Profils de noms clairement :<\/strong> Incluez la pi\u00e8ce, l\u2019ID du moniteur, la cible de luminance et la date dans le nom du profil pour faciliter les audits.<\/p>\n<\/li>\n<li data-start=\"7568\" data-end=\"7692\">\n<p data-start=\"7570\" data-end=\"7692\"><strong data-start=\"7570\" data-end=\"7594\">Suivre la lumi\u00e8re ambiante :<\/strong> M\u00eame dans les salles de lecture, les politiques de porte et l\u2019\u00e9clairage des t\u00e2ches peuvent accentuer le contraste per\u00e7u \u2014 consignez-le.<\/p>\n<\/li>\n<li data-start=\"7693\" data-end=\"7826\">\n<p data-start=\"7695\" data-end=\"7826\"><strong data-start=\"7695\" data-end=\"7723\">Listez les candidatures cliniques sur liste blanche :<\/strong> Assurez-vous que les param\u00e8tres de gestion des couleurs ne soient pas d\u00e9pass\u00e9s par les mises \u00e0 jour des visionneurs ; valider apr\u00e8s les mises \u00e0 jour PACS.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"7833\" data-end=\"7874\">Co\u00fbt et r\u00e9duction des risques, que vous pouvez quantifier<\/h2>\n<ul data-start=\"7876\" data-end=\"8255\">\n<li data-start=\"7876\" data-end=\"7971\">\n<p data-start=\"7878\" data-end=\"7971\"><strong data-start=\"7878\" data-end=\"7904\">Dur\u00e9e de vie prolong\u00e9e du moniteur :<\/strong> Maintenir les panneaux en service plus longtemps en compensant les d\u00e9rives dans le logiciel.<\/p>\n<\/li>\n<li data-start=\"7972\" data-end=\"8063\">\n<p data-start=\"7974\" data-end=\"8063\"><strong data-start=\"7974\" data-end=\"7998\">R\u00e9duction des roulis de camions :<\/strong> L\u2019application et la v\u00e9rification des politiques \u00e0 distance ont r\u00e9duit les visites sur site.<\/p>\n<\/li>\n<li data-start=\"8064\" data-end=\"8155\">\n<p data-start=\"8066\" data-end=\"8155\"><strong data-start=\"8066\" data-end=\"8087\">Temps d\u2019audit \u00e9conomis\u00e9 :<\/strong> Les exportations QA en un clic et les vues flotte remplacent les tableaux manuels.<\/p>\n<\/li>\n<li data-start=\"8156\" data-end=\"8255\">\n<p data-start=\"8158\" data-end=\"8255\"><strong data-start=\"8158\" data-end=\"8187\">Att\u00e9nuation des risques cliniques :<\/strong> Une d\u00e9tection pr\u00e9coce de la d\u00e9rive r\u00e9duit le risque de rat\u00e9s li\u00e9s au contraste.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"8262\" data-end=\"8303\">  Gouvernance et conformit\u00e9 : Faites en sorte que \u00e7a reste<\/h2>\n<ul data-start=\"8305\" data-end=\"8721\">\n<li data-start=\"8305\" data-end=\"8414\">\n<p data-start=\"8307\" data-end=\"8414\"><strong data-start=\"8307\" data-end=\"8328\">D\u00e9finir la propri\u00e9t\u00e9 :<\/strong> Assignez un responsable QA modalit\u00e9 (ou un physicien) par site, avec une supervision au niveau de l\u2019entreprise.<\/p>\n<\/li>\n<li data-start=\"8415\" data-end=\"8493\">\n<p data-start=\"8417\" data-end=\"8493\"><strong data-start=\"8417\" data-end=\"8435\">Politiques de serrure :<\/strong> Consid\u00e9rez les seuils et les plannings comme des documents contr\u00f4l\u00e9s.<\/p>\n<\/li>\n<li data-start=\"8494\" data-end=\"8632\">\n<p data-start=\"8496\" data-end=\"8632\"><strong data-start=\"8496\" data-end=\"8516\">Contr\u00f4le de version :<\/strong> Conservez des copies des profils et rapports ant\u00e9rieurs pendant au moins la p\u00e9riode de conservation que votre r\u00e9gulateur ou accr\u00e9ditateur attend.<\/p>\n<\/li>\n<li data-start=\"8633\" data-end=\"8721\">\n<p data-start=\"8635\" data-end=\"8721\"><strong data-start=\"8635\" data-end=\"8657\">Gestion du changement :<\/strong> Apr\u00e8s les mises \u00e0 jour GPU\/pilote ou PACS, d\u00e9clenchez une v\u00e9rification g\u00e9n\u00e9rale.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"8728\" data-end=\"8757\">Questions fr\u00e9quemment pos\u00e9es<\/h2>\n<p data-start=\"8759\" data-end=\"9235\"><strong data-start=\"8759\" data-end=\"8829\">Q : L\u2019\u00e9talonnage logiciel peut-il \u00e9galer la calibration \u00ab vraie \u00bb du mat\u00e9riel LUT ?<\/strong><br data-start=\"8829\" data-end=\"8832\"><strong data-start=\"8832\" data-end=\"8838\">Un:<\/strong> Dans de nombreux cas d\u2019utilisation, oui. Avec <strong data-start=\"8884\" data-end=\"8895\">des LUTs 3D<\/strong> haute r\u00e9solution int\u00e9gr\u00e9es dans <strong data-start=\"8908\" data-end=\"8928\">les liaisons ICC<\/strong> et des mesures robustes, vous pouvez obtenir la conformit\u00e9 GSDF et un excellent suivi en niveaux de gris \u2014 m\u00eame sur des panneaux \u00e9conomiques. Les LUTs mat\u00e9rielles peuvent \u00eatre avantageuses pour certaines contraintes d\u2019uniformit\u00e9 ou de panel natives, mais les approches ax\u00e9es sur le logiciel couvrent la majorit\u00e9 des besoins cliniques tout en r\u00e9duisant les co\u00fbts et les frictions.  <\/p>\n<p data-start=\"9237\" data-end=\"9450\"><strong data-start=\"9237\" data-end=\"9278\">Q : Cela va-t-il ralentir la visualisation des images ?<\/strong><br data-start=\"9278\" data-end=\"9281\"><strong data-start=\"9281\" data-end=\"9287\">Un:<\/strong> Les profils correctement d\u00e9ploy\u00e9s fonctionnent au niveau du syst\u00e8me d\u2019exploitation\/pilote et sont peu performants en calcul. Les GPU modernes g\u00e8rent les transformations LUT 3D avec une surcharge n\u00e9gligeable. <\/p>\n<p data-start=\"9452\" data-end=\"9685\"><strong data-start=\"9452\" data-end=\"9491\">Q : Qu\u2019en est-il des configurations multi-\u00e9crans ?<\/strong><br data-start=\"9491\" data-end=\"9494\"><strong data-start=\"9494\" data-end=\"9500\">Un:<\/strong> Chaque \u00e9cran re\u00e7oit sa propre mesure, profil et planning. QUBYX OS Tools conserve les identit\u00e9s par \u00e9cran et les historiques QA, utiles dans les salles de lecture avec un vieillissement asym\u00e9trique des panneaux. <\/p>\n<p data-start=\"9687\" data-end=\"9917\"><strong data-start=\"9687\" data-end=\"9726\">Q : \u00c0 quelle fr\u00e9quence devrions-nous recalibrer ?<\/strong><br data-start=\"9726\" data-end=\"9729\"><strong data-start=\"9729\" data-end=\"9735\">Un:<\/strong> Commencez par <strong data-start=\"9747\" data-end=\"9770\">une v\u00e9rification hebdomadaire<\/strong> et <strong data-start=\"9775\" data-end=\"9800\"><a href=\"https:\/\/www.beamex.com\/resources\/what-is-calibration\/\" target=\"_blank\" rel=\"noopener\">un calibrage<\/a> trimestriel<\/strong>. Resserrez la cadence pour la mammographie ou les panneaux plus anciens, et rel\u00e2chez les plannings pour un mat\u00e9riel tr\u00e8s stable apr\u00e8s analyse de tendances. <\/p>\n<h2 data-start=\"9924\" data-end=\"9951\">Liste de contr\u00f4le pour l\u2019adoption rapide<\/h2>\n<ul class=\"contains-task-list\" data-start=\"9953\" data-end=\"10420\">\n<li class=\"task-list-item\" data-start=\"9953\" data-end=\"10012\">\n<p data-start=\"9959\" data-end=\"10012\">Pr\u00e9sentoirs d\u2019inventaire ; \u00c9tiquette par salle et r\u00f4le clinique<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10013\" data-end=\"10063\">\n<p data-start=\"10019\" data-end=\"10063\">S\u00e9lectionner\/standardiser les instruments de mesure<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10064\" data-end=\"10129\">\n<p data-start=\"10070\" data-end=\"10129\">D\u00e9finir les cibles du GSDF et les seuils de r\u00e9ussite\/\u00e9chec par modalit\u00e9<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10130\" data-end=\"10194\">\n<p data-start=\"10136\" data-end=\"10194\">Pilote sur du mat\u00e9riel mixte (m\u00e9dical + commercial)<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10195\" data-end=\"10258\">\n<p data-start=\"10201\" data-end=\"10258\">Calendriers de d\u00e9ploiement (v\u00e9rifier chaque semaine, calibrer trimestriellement)<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10259\" data-end=\"10310\">\n<p data-start=\"10265\" data-end=\"10310\">Activez les tableaux de bord et les alertes automatiques pour le drift<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10311\" data-end=\"10374\">\n<p data-start=\"10317\" data-end=\"10374\">Former les champions locaux ; protocoles de proc\u00e9dure op\u00e9rationnelle standard et contr\u00f4le des modifications<\/p>\n<\/li>\n<li class=\"task-list-item\" data-start=\"10375\" data-end=\"10420\">\n<p data-start=\"10381\" data-end=\"10420\">Profils d\u2019archives et rapports pour les audits<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"10427\" data-end=\"10442\">Le point \u00e0 retenir<\/h2>\n<p data-start=\"10444\" data-end=\"10837\"><strong data-start=\"10444\" data-end=\"10462\">QUBYX OS Tools<\/strong> propose une <strong data-start=\"10474\" data-end=\"10512\">voie non intrusive, ax\u00e9e sur le logiciel,<\/strong> vers la conformit\u00e9 DICOM GSDF, qui s\u2019\u00e9tend d\u2019une seule salle de lecture \u00e0 une flotte mondiale de t\u00e9l\u00e9radiologie. En vous appuyant sur <strong data-start=\"10626\" data-end=\"10676\">des profils de liaison de p\u00e9riph\u00e9rique ICC avec des LUT 3D int\u00e9gr\u00e9s<\/strong>, une v\u00e9rification automatis\u00e9e et des rapports pr\u00eats \u00e0 l\u2019audit, vous maintenez la qualit\u00e9 d\u2019image \u00e0 sa place \u2014 <strong data-start=\"10769\" data-end=\"10780\">en sp\u00e9cification<\/strong> \u2014 tout en r\u00e9duisant les co\u00fbts, les temps d\u2019arr\u00eat et les frictions op\u00e9rationnelles. <\/p>\n<h3 data-start=\"8543\" data-end=\"8565\"><strong data-start=\"8547\" data-end=\"8565\">Appel \u00e0 l\u2019action<\/strong><\/h3>\n<p data-start=\"8567\" data-end=\"8805\">D\u00e9couvrez les <strong data-start=\"8587\" data-end=\"8605\">outils QUBYX OS<\/strong> et <strong data-start=\"8610\" data-end=\"8630\">la suite PerfectLum<\/strong> \u2014 les solutions les plus avanc\u00e9es de logiciels de Claibration pour les environnements de radiologie, t\u00e9l\u00e9radiologie et imagerie clinique.<br data-start=\"8752\" data-end=\"8755\">Visitez <strong data-start=\"8761\" data-end=\"8803\"><a class=\"decorated-link cursor-pointer\" href=\"https:\/\/qubyx.com\/fr\/\" target=\"_new\" rel=\"noopener\" data-start=\"8763\" data-end=\"8801\">www.qubyx.com<\/a><\/strong><\/p>\n<p data-start=\"8567\" data-end=\"8805\">Pour garantir une pr\u00e9cision d\u2019affichage de qualit\u00e9 m\u00e9dicale tout en r\u00e9duisant les co\u00fbts r\u00e9currents du mat\u00e9riel propri\u00e9taire, la r\u00e9ponse est claire : passer d\u00e8s aujourd\u2019hui \u00e0 une <mark>plateforme logicielle d\u2019\u00e9talonnage <\/mark>comme <a href=\"https:\/\/qubyx.com\/fr\/outils-qubyx-os\/\"><b>QUBYX OS Tools<\/b><\/a> (Free) et <a href=\"https:\/\/qubyx.com\/products-perfectlum-4\/\"><b>PerfectLum<\/b><\/a> .<\/p>\n<p><b> <\/b><\/p>\n<p data-start=\"5644\" data-end=\"5884\"><strong>\u00c9tiquettes:<\/strong><\/p>\n<p data-start=\"293\" data-end=\"658\">Outils QUBYX OS, logiciel d\u2019\u00e9talonnage DICOM, QA d\u2019affichage m\u00e9dical, conformit\u00e9 DICOM GSDF, outils d\u2019\u00e9talonnage logiciel, assurance qualit\u00e9 d\u2019affichage, \u00e9talonnage non intrusif, profils de liaison ICC de dispositifs, calibration LUT 3D, logiciels d\u2019imagerie m\u00e9dicale, QUBYX PerfectLum, \u00e9talonnage d\u2019affichage diagnostique, contr\u00f4le qualit\u00e9 du moniteur radiologique, outils d\u2019\u00e9talonnage IT en sant\u00e9, \u00e9talonnage d\u2019affichage m\u00e9dical aux \u00c9tats-Unis, conformit\u00e9 DICOM USA, logiciel QA en radiologie aux \u00c9tats-Unis, maintenance d\u2019affichage hospitalier aux \u00c9tats-Unis,  outils d\u2019imagerie QA USA, logiciel d\u2019\u00e9talonnage de sant\u00e9 USA, qubyx USA, \u00e9talonnage d\u2019affichage diagnostique USA<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Explication des outils QUBYX OS | La mani\u00e8re non intrusive de maintenir les normes DICOM &nbsp; Lorsque les d\u00e9cisions cliniques [&hellip;]<\/p>\n","protected":false},"author":770,"featured_media":14114,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1250,1252,1251,1292],"tags":[5124,5119,5116,5125,5127,5126,5017,5115,5114,5113,1757,5123,5112,5121,5117,5111,1483,5122,5120,5118],"class_list":["post-14112","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actualites","category-logiciel-qubyx","category-perfectlum","category-qubyx-os","tag-affichage-medical-abordable-qa-usa","tag-assurance-qualite-de-limagerie-diagnostique","tag-calibration-des-liaisons-de-dispositifs-icc","tag-conformite-dicom-gsdf-basee-sur-le-logiciel","tag-controle-qualite-automatise-pour-les-affichages-de-diagnostic","tag-etalonnage-a-distance-pour-moniteurs-de-radiologie","tag-etalonnage-des-ecrans-medicaux-aux-etats-unis","tag-etalonnage-daffichage-non-intrusif","tag-logiciel-de-conformite-dicom-gsdf","tag-logiciel-dassurance-qualite-de-laffichage-radiologique","tag-logiciel-detalonnage-dicom","tag-meilleur-logiciel-detalonnage-dicom-pour-les-hopitaux","tag-outil-de-calibration-des-moniteurs-hospitaliers","tag-outils-detalonnage-dicom-open-source","tag-profilage-medical-3d-lut","tag-qubyx-os-outils-usa","tag-qubyx-perfectlum","tag-solution-detalonnage-daffichage-pacs","tag-solutions-informatiques-en-radiologie-aux-etats-unis","tag-systeme-detalonnage-dabord-logiciel"],"acf":[],"_links":{"self":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts\/14112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/users\/770"}],"replies":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/comments?post=14112"}],"version-history":[{"count":0,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts\/14112\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/media\/14114"}],"wp:attachment":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/media?parent=14112"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/categories?post=14112"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/tags?post=14112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}