{"id":12469,"date":"2025-10-13T09:25:05","date_gmt":"2025-10-13T09:25:05","guid":{"rendered":"https:\/\/qubyx.com\/etalonnage-logiciel-qubyx-pour-les-ecrans-hospitaliers\/"},"modified":"2025-10-13T09:25:05","modified_gmt":"2025-10-13T09:25:05","slug":"etalonnage-logiciel-qubyx-pour-les-ecrans-hospitaliers","status":"publish","type":"post","link":"https:\/\/qubyx.com\/fr\/etalonnage-logiciel-qubyx-pour-les-ecrans-hospitaliers\/","title":{"rendered":"\u00c9talonnage logiciel QUBYX pour les \u00e9crans hospitaliers"},"content":{"rendered":"<h2 style=\"text-align: center;\" data-start=\"0\" data-end=\"102\">Coupez le cordon : comment la calibration logicielle de QUBYX remplace le mat\u00e9riel co\u00fbteux dans la gestion de l\u2019affichage hospitalier<\/h2>\n<p>&nbsp;<\/p>\n<p data-start=\"104\" data-end=\"692\"><strong data-start=\"104\" data-end=\"125\">R\u00e9sum\u00e9 ex\u00e9cutif<\/strong><br data-start=\"125\" data-end=\"128\">Les h\u00f4pitaux n\u2019ont pas besoin d\u2019acheter sans cesse des moniteurs \u00ab calibr\u00e9s mat\u00e9riellement \u00bb haut de gamme pour r\u00e9pondre aux normes de qualit\u00e9 diagnostique. Une strat\u00e9gie ax\u00e9e sur le logiciel \u2014 ancr\u00e9e par <strong data-start=\"277\" data-end=\"295\">QUBYX OS Tools<\/strong> (utilitaires open source) et <strong data-start=\"324\" data-end=\"338\">PerfectLum<\/strong> (\u00e9talonnage et contr\u00f4le qualit\u00e9 en entreprise) \u2014 offre une r\u00e9ponse de luminance conforme \u00e0 DICOM, une automatisation QA robuste et un contr\u00f4le centralis\u00e9 de flotte sur des \u00e9crans bien plus \u00e9conomiques. Le r\u00e9sultat : co\u00fbt total de possession (TCO) plus faible, d\u00e9ploiements plus rapides et une qualit\u00e9 d\u2019image coh\u00e9rente en radiologie, mammographie, chirurgie, urgences, t\u00e9l\u00e9radiologie et cliniques \u2014 sans engagement du fournisseur.  <\/p>\n<h2 data-start=\"699\" data-end=\"753\">Pourquoi les programmes d\u2019affichage centr\u00e9s sur le mat\u00e9riel \u00e9puisent les budgets<\/h2>\n<p data-start=\"755\" data-end=\"890\">Les approches traditionnelles supposent que la qualit\u00e9 n\u00e9cessite des \u00e9crans co\u00fbteux avec des LUTs int\u00e9gr\u00e9es et des sondes sp\u00e9cifiques au fournisseur. Les co\u00fbts cach\u00e9s s\u2019accumulent : <\/p>\n<ul data-start=\"892\" data-end=\"1352\">\n<li data-start=\"892\" data-end=\"1016\">\n<p data-start=\"894\" data-end=\"1016\"><strong data-start=\"894\" data-end=\"912\">Suppl\u00e9ment CapEx :<\/strong> Les moniteurs de diagnostic \u00e9quip\u00e9s de LUTs mat\u00e9riels propri\u00e9taires peuvent co\u00fbter de 2 \u00e0 4 \u00d7 de plus que les panneaux commerciaux performants.<\/p>\n<\/li>\n<li data-start=\"1017\" data-end=\"1129\">\n<p data-start=\"1019\" data-end=\"1129\"><strong data-start=\"1019\" data-end=\"1040\">\u00c9talement accessoire :<\/strong> Les palets verrouill\u00e9s par la marque, colorim\u00e8tres, licences et pi\u00e8ces de rechange ajoutent des d\u00e9penses r\u00e9currentes.<\/p>\n<\/li>\n<li data-start=\"1130\" data-end=\"1246\">\n<p data-start=\"1132\" data-end=\"1246\"><strong data-start=\"1132\" data-end=\"1150\">QA fragment\u00e9 :<\/strong> Des outils et des tableaux mixtes entra\u00eenent des lacunes de conformit\u00e9, des calibrations retard\u00e9es et un stress d\u2019audit.<\/p>\n<\/li>\n<li data-start=\"1247\" data-end=\"1352\">\n<p data-start=\"1249\" data-end=\"1352\"><strong data-start=\"1249\" data-end=\"1268\">Verrouillage du fournisseur :<\/strong> Chaque \u00e9cosyst\u00e8me mat\u00e9riel exige ses propres logiciels, flux de travail et contrats de service.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1354\" data-end=\"1471\">L\u2019impact sur l\u2019entreprise : d\u00e9pr\u00e9ciation plus \u00e9lev\u00e9e, cycles de rafra\u00eechissement plus longs et qualit\u00e9 d\u2019image in\u00e9gale \u00e0 mesure que les appareils vieillissent d\u00e9synchronis\u00e9s.<\/p>\n<h2 data-start=\"1478\" data-end=\"1530\">L\u2019alternative ax\u00e9e sur le logiciel (et pourquoi elle fonctionne)<\/h2>\n<p data-start=\"1532\" data-end=\"1727\"><strong data-start=\"1532\" data-end=\"1556\">La calibration logicielle<\/strong> aligne la sortie d\u2019affichage aux standards via des LUT contr\u00f4l\u00e9s par logiciel, des flux de travail ICC\/3D-LUT et une assurance qualit\u00e9 programm\u00e9e \u2014 ind\u00e9pendamment du firmware sp\u00e9cifique du moniteur. Avec QUBYX, vous obtenez : <\/p>\n<ol data-start=\"1729\" data-end=\"2348\">\n<li data-start=\"1729\" data-end=\"1856\">\n<p data-start=\"1732\" data-end=\"1856\"><strong data-start=\"1732\" data-end=\"1775\">Luminance et niveaux de gris pilot\u00e9s par les standards :<\/strong> Ciblez la r\u00e9ponse GSDF DICOM Part 14 sans avoir besoin d\u2019une LUT interne propri\u00e9taire.<\/p>\n<\/li>\n<li data-start=\"1857\" data-end=\"2030\">\n<p data-start=\"1860\" data-end=\"2030\"><strong data-start=\"1860\" data-end=\"1896\">Pr\u00e9cision des couleurs l\u00e0 o\u00f9 cela compte :<\/strong> Pour les modalit\u00e9s de couleur (par exemple, cardiologie, visionneuses de pathologie, chirurgie), les pipelines ICC\/3D-LUT offrent une performance chromatique constante.<\/p>\n<\/li>\n<li data-start=\"2031\" data-end=\"2176\">\n<p data-start=\"2034\" data-end=\"2176\"><strong data-start=\"2034\" data-end=\"2059\">QA centralis\u00e9e de la flotte :<\/strong> Des plannings guid\u00e9s par des politiques, des contr\u00f4les automatis\u00e9s et des tableaux de bord clairs de r\u00e9ussite\/\u00e9chec maintiennent les appareils conformes et pr\u00eats pour les enqu\u00eates.<\/p>\n<\/li>\n<li data-start=\"2177\" data-end=\"2348\">\n<p data-start=\"2180\" data-end=\"2348\"><strong data-start=\"2180\" data-end=\"2201\">Libert\u00e9 mat\u00e9rielle :<\/strong> Choisissez des panneaux \u00e9conomiques qui respectent les crit\u00e8res de luminosit\u00e9 et de profondeur de bits, et \u00e9vitez le verrouillage du fournisseur tout en obtenant des performances de qualit\u00e9 diagnostique.<\/p>\n<\/li>\n<\/ol>\n<h2 data-start=\"2355\" data-end=\"2378\">Voici la pile QUBYX<\/h2>\n<h3 data-start=\"2380\" data-end=\"2412\">Outils QUBYX OS (Open Source)<\/h3>\n<ul data-start=\"2413\" data-end=\"2652\">\n<li data-start=\"2413\" data-end=\"2500\">\n<p data-start=\"2415\" data-end=\"2500\"><strong data-start=\"2415\" data-end=\"2427\">Objectif :<\/strong> Utilitaires Foundation pour la g\u00e9n\u00e9ration de liaison de p\u00e9riph\u00e9rique ICC et les flux de travail LUT.<\/p>\n<\/li>\n<li data-start=\"2501\" data-end=\"2652\">\n<p data-start=\"2503\" data-end=\"2652\"><strong data-start=\"2503\" data-end=\"2513\">Valeur :<\/strong> Ouverture = transparence, auditabilit\u00e9 et durabilit\u00e9 \u00e0 long terme. Votre \u00e9quipe peut standardiser les pipelines et \u00e9viter les d\u00e9pendances de bo\u00eete noire. <\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2654\" data-end=\"2698\">PerfectLum (\u00c9talonnage d\u2019entreprise &amp; QA)<\/h3>\n<ul data-start=\"2699\" data-end=\"3162\">\n<li data-start=\"2699\" data-end=\"2775\">\n<p data-start=\"2701\" data-end=\"2775\"><strong data-start=\"2701\" data-end=\"2713\">Objectif :<\/strong> Moteur de calibration\/QA de qualit\u00e9 de production pour les flottes hospitali\u00e8res.<\/p>\n<\/li>\n<li data-start=\"2776\" data-end=\"3072\">\n<p data-start=\"2778\" data-end=\"2799\"><strong data-start=\"2778\" data-end=\"2797\">Fonctions principales :<\/strong><\/p>\n<ul data-start=\"2802\" data-end=\"3072\">\n<li data-start=\"2802\" data-end=\"2845\">\n<p data-start=\"2804\" data-end=\"2845\">\u00c9talonnage et v\u00e9rification du DICOM GSDF<\/p>\n<\/li>\n<li data-start=\"2848\" data-end=\"2893\">\n<p data-start=\"2850\" data-end=\"2893\">Contr\u00f4les automatis\u00e9s de luminance et d\u2019uniformit\u00e9<\/p>\n<\/li>\n<li data-start=\"2896\" data-end=\"2954\">\n<p data-start=\"2898\" data-end=\"2954\">Planificateur pour les t\u00e2ches QA p\u00e9riodiques (quotidiennes\/hebdomadaires\/mensuelles)<\/p>\n<\/li>\n<li data-start=\"2957\" data-end=\"3021\">\n<p data-start=\"2959\" data-end=\"3021\">Rapports centralis\u00e9s pour les audits et la pr\u00e9paration \u00e0 l\u2019accr\u00e9ditation<\/p>\n<\/li>\n<li data-start=\"3024\" data-end=\"3072\">\n<p data-start=\"3026\" data-end=\"3072\">Ex\u00e9cution \u00e0 distance pour les terminaux de t\u00e9l\u00e9radiologie<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"3073\" data-end=\"3162\">\n<p data-start=\"3075\" data-end=\"3162\"><strong data-start=\"3075\" data-end=\"3086\">R\u00e9sultat :<\/strong> Un centre de commandement unifi\u00e9 pour la conformit\u00e9, la qualit\u00e9 et la visibilit\u00e9 sur le cycle de vie.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"3169\" data-end=\"3210\">\u00c0 quoi ressemble un \u00ab mat\u00e9riel suffisamment bon \u00bb<\/h2>\n<p data-start=\"3212\" data-end=\"3292\">Vous n\u2019avez pas besoin des moniteurs les plus chers \u2014 mais vous avez besoin de capacit\u00e9s minimales :<\/p>\n<ul data-start=\"3294\" data-end=\"3800\">\n<li data-start=\"3294\" data-end=\"3445\">\n<p data-start=\"3296\" data-end=\"3445\"><strong data-start=\"3296\" data-end=\"3318\">Performance du panel :<\/strong> Courbe de luminance stable, luminosit\u00e9 maximale ad\u00e9quate pour l\u2019environnement clinique, et uniformit\u00e9 qui peut \u00eatre corrig\u00e9e ou g\u00e9r\u00e9e.<\/p>\n<\/li>\n<li data-start=\"3446\" data-end=\"3535\">\n<p data-start=\"3448\" data-end=\"3535\"><strong data-start=\"3448\" data-end=\"3474\">Profondeur de bits et interface :<\/strong> prise en charge des chemins 10 bits lorsque cela est applicable pour des gradients limpos.<\/p>\n<\/li>\n<li data-start=\"3536\" data-end=\"3671\">\n<p data-start=\"3538\" data-end=\"3671\"><strong data-start=\"3538\" data-end=\"3558\">Strat\u00e9gie des capteurs :<\/strong> Utilisez un colorim\u00e8tre externe support\u00e9 pour l\u2019\u00e9talonnage initial et les contr\u00f4les programm\u00e9s (centralis\u00e9s par PerfectLum).<\/p>\n<\/li>\n<li data-start=\"3672\" data-end=\"3800\">\n<p data-start=\"3674\" data-end=\"3800\"><strong data-start=\"3674\" data-end=\"3701\">Gestion de l\u2019environnement :<\/strong> Contr\u00f4ler la lumi\u00e8re ambiante ou utiliser des politiques de compensation de la lumi\u00e8re ambiante pour prot\u00e9ger la pr\u00e9sentation en copies logicielles.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3802\" data-end=\"3932\">Lorsque ces bases sont en place, l\u2019\u00e9talonnage logiciel peut atteindre \u2014 et maintenir \u2014 la conformit\u00e9 aux normes \u00e0 une fraction des co\u00fbts h\u00e9rit\u00e9s.<\/p>\n<h2 data-start=\"3939\" data-end=\"3969\">Ob\u00e9issance sans douleur<\/h2>\n<p data-start=\"3971\" data-end=\"4043\">Un programme ax\u00e9 sur le logiciel correspond parfaitement aux directives les plus r\u00e9f\u00e9renc\u00e9es :<\/p>\n<ul data-start=\"4045\" data-end=\"4377\">\n<li data-start=\"4045\" data-end=\"4148\">\n<p data-start=\"4047\" data-end=\"4148\"><strong data-start=\"4047\" data-end=\"4070\">DICOM Partie 14 GSDF :<\/strong> \u00c9talonnage et v\u00e9rification des fonctions d\u2019affichage en niveaux de gris pour une utilisation diagnostique.<\/p>\n<\/li>\n<li data-start=\"4149\" data-end=\"4270\">\n<p data-start=\"4151\" data-end=\"4270\"><strong data-start=\"4151\" data-end=\"4173\">AAPM TG18 \/ TG270 :<\/strong> Conseils pour les tests d\u2019acceptation et de constance ; Les routines de PerfectLum correspondent aux besoins p\u00e9riodiques de contr\u00f4le qualit\u00e9.<\/p>\n<\/li>\n<li data-start=\"4271\" data-end=\"4377\">\n<p data-start=\"4273\" data-end=\"4377\"><strong data-start=\"4273\" data-end=\"4311\">DIN 6868-157\/-57 et politiques locales :<\/strong> Prise en charge des protocoles r\u00e9gionaux et d\u2019une tenue de registres favorable aux audits.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4379\" data-end=\"4504\"><strong data-start=\"4379\" data-end=\"4398\">La pr\u00e9paration \u00e0 l\u2019audit<\/strong> n\u2019est plus une course folle ; Vos rapports, v\u00e9rifications de constance et historiques d\u2019\u00e9carts sont g\u00e9n\u00e9r\u00e9s \u00e0 la demande.<\/p>\n<h2 data-start=\"4511\" data-end=\"4553\">Co\u00fbts &amp; Op\u00e9rations : un aper\u00e7u rapide du TCO<\/h2>\n<div class=\"_tableContainer_1rjym_1\">\n<div class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4555\" data-end=\"5166\">\n<thead data-start=\"4555\" data-end=\"4624\">\n<tr data-start=\"4555\" data-end=\"4624\">\nFacteur <\/p>\n<th data-start=\"4555\" data-end=\"4569\" data-col-size=\"sm\">de co\u00fbt<\/th>\n<p>Flotte <\/p>\n<th data-start=\"4569\" data-end=\"4594\" data-col-size=\"sm\">centr\u00e9e sur le mat\u00e9riel<\/th>\n<th data-start=\"4594\" data-end=\"4624\" data-col-size=\"sm\">QUBYX Software &#8211; Flotte d\u2019abord<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4639\" data-end=\"5166\">\n<tr data-start=\"4639\" data-end=\"4726\">\n<td data-start=\"4639\" data-end=\"4655\" data-col-size=\"sm\">Display CapEx<\/td>\n<td data-start=\"4655\" data-end=\"4685\" data-col-size=\"sm\">\u00c9lev\u00e9 (propri\u00e9taire, premium)<\/td>\n<td data-start=\"4685\" data-end=\"4726\" data-col-size=\"sm\">Mod\u00e9r\u00e9 (commissions commerciales approuv\u00e9es)<\/td>\n<\/tr>\n<tr data-start=\"4727\" data-end=\"4812\">\n\u00c9quipement <\/p>\n<td data-start=\"4727\" data-end=\"4746\" data-col-size=\"sm\">d\u2019\u00e9talonnage<\/td>\n<td data-start=\"4746\" data-end=\"4771\" data-col-size=\"sm\">Verrouill\u00e9 par la marque, plusieurs<\/td>\n<td data-start=\"4771\" data-end=\"4812\" data-col-size=\"sm\">Un colorim\u00e8tre standard sur toute la flotte<\/td>\n<\/tr>\n<tr data-start=\"4813\" data-end=\"4892\">\n<td data-start=\"4813\" data-end=\"4833\" data-col-size=\"sm\">Licences logicielles<\/td>\n<td data-start=\"4833\" data-end=\"4857\" data-col-size=\"sm\">Fragment\u00e9 par fournisseur<\/td>\n<td data-start=\"4857\" data-end=\"4892\" data-col-size=\"sm\">Plateforme QA unique (PerfectLum)<\/td>\n<\/tr>\n<tr data-start=\"4893\" data-end=\"4959\">\n<td data-start=\"4893\" data-end=\"4904\" data-col-size=\"sm\">QA Labor<\/td>\n<td data-start=\"4904\" data-end=\"4924\" data-col-size=\"sm\">Manuel, par<\/td>\n<p> morceaux<\/p>\n<td data-start=\"4924\" data-end=\"4959\" data-col-size=\"sm\">Plannings automatis\u00e9s et contr\u00f4le qualit\u00e9 \u00e0 distance<\/td>\n<\/tr>\n<tr data-start=\"4960\" data-end=\"5008\">\n<td data-start=\"4960\" data-end=\"4977\" data-col-size=\"sm\">Verrouillage<\/td>\n<p> du fournisseur<\/p>\n<td data-start=\"4977\" data-end=\"4984\" data-col-size=\"sm\">Haut<\/td>\n<td data-start=\"4984\" data-end=\"5008\" data-col-size=\"sm\">Faible (flux de travail ouverts)<\/td>\n<\/tr>\n<tr data-start=\"5009\" data-end=\"5092\">\nPr\u00e9paration <\/p>\n<td data-start=\"5009\" data-end=\"5029\" data-col-size=\"sm\">\u00e0 l\u2019audit<\/td>\n<td data-start=\"5029\" data-end=\"5054\" data-col-size=\"sm\">Improvis\u00e9,<\/td>\n<p> chronophage<\/p>\n<td data-start=\"5054\" data-end=\"5092\" data-col-size=\"sm\">Rapports en un clic, journaux coh\u00e9rents<\/td>\n<\/tr>\n<tr data-start=\"5093\" data-end=\"5166\">\nCycle <\/p>\n<td data-start=\"5093\" data-end=\"5105\" data-col-size=\"sm\">de vie<\/td>\n<td data-start=\"5105\" data-end=\"5126\" data-col-size=\"sm\">Remplacez-le par une marque<\/td>\n<td data-start=\"5126\" data-end=\"5166\" data-col-size=\"sm\">Prolonger la dur\u00e9e de vie utile par recalibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"5168\" data-end=\"5298\">Les h\u00f4pitaux constatent g\u00e9n\u00e9ralement <strong data-start=\"5192\" data-end=\"5216\">une r\u00e9duction de 30 \u00e0 60 % du TCO<\/strong> sur un cycle de renouvellement, selon le m\u00e9lange h\u00e9rit\u00e9, la taille de la flotte et la maturit\u00e9 du flux de travail.<\/p>\n<h2 data-start=\"5305\" data-end=\"5349\">Feuille de route de mise en \u0153uvre (90 jours avant la valeur)<\/h2>\n<p data-start=\"5351\" data-end=\"5385\"><strong data-start=\"5351\" data-end=\"5383\">Jours 0 \u00e0 15 : \u00c9valuation &amp; R\u00e9f\u00e9rence<\/strong><\/p>\n<ul data-start=\"5386\" data-end=\"5586\">\n<li data-start=\"5386\" data-end=\"5453\">\n<p data-start=\"5388\" data-end=\"5453\">Affichages d\u2019inventaire (mod\u00e8le, \u00e2ge, luminosit\u00e9, emplacement).<\/p>\n<\/li>\n<li data-start=\"5454\" data-end=\"5513\">\n<p data-start=\"5456\" data-end=\"5513\">Faites des tests d\u2019acceptation\/constance jusqu\u2019\u00e0 la performance de base.<\/p>\n<\/li>\n<li data-start=\"5514\" data-end=\"5586\">\n<p data-start=\"5516\" data-end=\"5586\">Identifiez les risques li\u00e9s \u00e0 la lumi\u00e8re ambiante, les politiques de gradation et les besoins en signalisation des pi\u00e8ces.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5588\" data-end=\"5611\"><strong data-start=\"5588\" data-end=\"5609\">Jours 16 \u00e0 30 : Pilote<\/strong><\/p>\n<ul data-start=\"5612\" data-end=\"5916\">\n<li data-start=\"5612\" data-end=\"5713\">\n<p data-start=\"5614\" data-end=\"5713\">S\u00e9lectionnez 10 \u00e0 20 affichages selon les modalit\u00e9s (par exemple, 3 radiologie, 4 chirurgie, 3 urgences, 5 cliniques g\u00e9n\u00e9rales).<\/p>\n<\/li>\n<li data-start=\"5714\" data-end=\"5786\">\n<p data-start=\"5716\" data-end=\"5786\">Installer QUBYX OS Tools et PerfectLum ; Connectez un colorim\u00e8tre standard.<\/p>\n<\/li>\n<li data-start=\"5787\" data-end=\"5843\">\n<p data-start=\"5789\" data-end=\"5843\">Calibrer en DICOM GSDF ; Mettez en place des contr\u00f4les QA hebdomadaires.<\/p>\n<\/li>\n<li data-start=\"5844\" data-end=\"5916\">\n<p data-start=\"5846\" data-end=\"5916\">Validez les images avec les radiologues\/cliniciens (boucle de r\u00e9troaction de l\u2019observateur).<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5918\" data-end=\"5941\"><strong data-start=\"5918\" data-end=\"5939\">Jours 31\u201360 : \u00c9chelle<\/strong><\/p>\n<ul data-start=\"5942\" data-end=\"6157\">\n<li data-start=\"5942\" data-end=\"6025\">\n<p data-start=\"5944\" data-end=\"6025\">D\u00e9ploie des mod\u00e8les de politiques (cadence d\u2019\u00e9talonnage, objectifs de luminosit\u00e9, r\u00e9ussite\/\u00e9chec).<\/p>\n<\/li>\n<li data-start=\"6026\" data-end=\"6086\">\n<p data-start=\"6028\" data-end=\"6086\">Activez l\u2019assurance qualit\u00e9 \u00e0 distance pour la t\u00e9l\u00e9radiologie et les cliniques hors site.<\/p>\n<\/li>\n<li data-start=\"6087\" data-end=\"6157\">\n<p data-start=\"6089\" data-end=\"6157\">G\u00e9n\u00e9rez des rapports de conformit\u00e9 initiaux et ajustez les seuils si n\u00e9cessaire.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"6159\" data-end=\"6185\"><strong data-start=\"6159\" data-end=\"6183\">Jours 61\u201390 : Optimiser<\/strong><\/p>\n<ul data-start=\"6186\" data-end=\"6379\">\n<li data-start=\"6186\" data-end=\"6245\">\n<p data-start=\"6188\" data-end=\"6245\">Utilisez les tableaux de bord de flotte pour rep\u00e9rer le drift et les sous-performances.<\/p>\n<\/li>\n<li data-start=\"6246\" data-end=\"6298\">\n<p data-start=\"6248\" data-end=\"6298\">Ajustez les normes de lumi\u00e8re ambiante et la formation du personnel.<\/p>\n<\/li>\n<li data-start=\"6299\" data-end=\"6379\">\n<p data-start=\"6301\" data-end=\"6379\">\u00c9tablissez une politique de mise \u00e0 jour bas\u00e9e sur des r\u00e9sultats mesurables en assurance qualit\u00e9 \u2014 et non sur des obligations de marque.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"6386\" data-end=\"6438\">Qualit\u00e9 clinique : ce qui change (et ce qui ne change pas)<\/h2>\n<p data-start=\"6440\" data-end=\"6459\"><strong data-start=\"6440\" data-end=\"6457\">Qu\u2019est-ce qui s\u2019am\u00e9liore<\/strong><\/p>\n<ul data-start=\"6460\" data-end=\"6643\">\n<li data-start=\"6460\" data-end=\"6515\">\n<p data-start=\"6462\" data-end=\"6515\">R\u00e9gularit\u00e9 entre les salles, b\u00e2timents et t\u00e9l\u00e9sites<\/p>\n<\/li>\n<li data-start=\"6516\" data-end=\"6586\">\n<p data-start=\"6518\" data-end=\"6586\">D\u00e9tection de probl\u00e8me plus rapide (d\u00e9rive, non-uniformit\u00e9, violations ambiantes)<\/p>\n<\/li>\n<li data-start=\"6587\" data-end=\"6643\">\n<p data-start=\"6589\" data-end=\"6643\">Confiance dans la relecture et la comparaison en copies digitales au fil du temps<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"6645\" data-end=\"6670\"><strong data-start=\"6645\" data-end=\"6668\">Ce qui reste pareil<\/strong><\/p>\n<ul data-start=\"6671\" data-end=\"6855\">\n<li data-start=\"6671\" data-end=\"6740\">\n<p data-start=\"6673\" data-end=\"6740\">La responsabilit\u00e9 clinique et le jugement final restent entre les mains des m\u00e9decins<\/p>\n<\/li>\n<li data-start=\"6741\" data-end=\"6793\">\n<p data-start=\"6743\" data-end=\"6793\">Les politiques de modalit\u00e9 QA et PACS se poursuivent comme auparavant<\/p>\n<\/li>\n<li data-start=\"6794\" data-end=\"6855\">\n<p data-start=\"6796\" data-end=\"6855\">Vos exigences d\u2019accr\u00e9ditation \u2014 d\u00e9sormais beaucoup plus faciles \u00e0 documenter<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"6862\" data-end=\"6888\">D\u00e9mystifier les 5 mythes principaux<\/h2>\n<ol data-start=\"6890\" data-end=\"7580\">\n<li data-start=\"6890\" data-end=\"7053\">\n<p data-start=\"6893\" data-end=\"7053\"><strong data-start=\"6893\" data-end=\"6953\">\u00ab Seuls les moniteurs avec LUTs internes sont de qualit\u00e9 diagnostique. \u00bb<\/strong><br data-start=\"6953\" data-end=\"6956\">L\u2019\u00e9talonnage logiciel peut atteindre des objectifs GSDF avec des m\u00e9thodes LUT\/ICC externes et une assurance qualit\u00e9 continue.<\/p>\n<\/li>\n<li data-start=\"7055\" data-end=\"7152\">\n<p data-start=\"7058\" data-end=\"7152\"><strong data-start=\"7058\" data-end=\"7090\">\u00ab Le contr\u00f4le qualit\u00e9 doit \u00eatre sp\u00e9cifique \u00e0 la marque. \u00bb<\/strong><br data-start=\"7090\" data-end=\"7093\">PerfectLum centralise l\u2019assurance qualit\u00e9 entre flottes et sites mixtes.<\/p>\n<\/li>\n<li data-start=\"7154\" data-end=\"7309\">\n<p data-start=\"7157\" data-end=\"7309\"><strong data-start=\"7157\" data-end=\"7187\">\u00ab Open source signifie risqu\u00e9. \u00bb<\/strong><br data-start=\"7187\" data-end=\"7190\">Les outils QUBYX OS offrent transparence, auditabilit\u00e9 et r\u00e9silience communautaire \u2014 associ\u00e9s \u00e0 PerfectLum de qualit\u00e9 commerciale.<\/p>\n<\/li>\n<li data-start=\"7311\" data-end=\"7443\">\n<p data-start=\"7314\" data-end=\"7443\"><strong data-start=\"7314\" data-end=\"7351\">\u00ab Les sites isol\u00e9s ne peuvent pas \u00eatre v\u00e9rifi\u00e9s. \u00bb<\/strong><br data-start=\"7351\" data-end=\"7354\">Les tests programm\u00e9s, les d\u00e9clencheurs \u00e0 distance et les rapports automatiques rendent la QA en t\u00e9l\u00e9radiologie une routine.<\/p>\n<\/li>\n<li data-start=\"7445\" data-end=\"7580\">\n<p data-start=\"7448\" data-end=\"7580\"><strong data-start=\"7448\" data-end=\"7487\">\u00ab Les audits perturbent toujours les op\u00e9rations. \u00bb<\/strong><br data-start=\"7487\" data-end=\"7490\">Avec des tableaux de bord vivants et des exportations ponctuelles, la conformit\u00e9 est un clic\u2014pas une b\u00eatise.<\/p>\n<\/li>\n<\/ol>\n<h2 data-start=\"7587\" data-end=\"7619\">Liste de contr\u00f4le Gouvernance et Politiques<\/h2>\n<ul data-start=\"7621\" data-end=\"8066\">\n<li data-start=\"7621\" data-end=\"7665\">\n<p data-start=\"7623\" data-end=\"7665\">\u25a1 Cible et tol\u00e9rances DICOM GSDF d\u00e9finies<\/p>\n<\/li>\n<li data-start=\"7666\" data-end=\"7721\">\n<p data-start=\"7668\" data-end=\"7721\">\u25a1 Limites de lumi\u00e8re ambiante et signalisation dans les salles de lecture<\/p>\n<\/li>\n<li data-start=\"7722\" data-end=\"7786\">\n<p data-start=\"7724\" data-end=\"7786\">\u25a1 Contr\u00f4les de constance trimestriels (ou plus stricts, selon le risque modal)<\/p>\n<\/li>\n<li data-start=\"7787\" data-end=\"7855\">\n<p data-start=\"7789\" data-end=\"7855\">\u25a1 Flux de travail d\u2019incident pour d\u00e9rive\/d\u00e9faillance (ticketing + recalibrage)<\/p>\n<\/li>\n<li data-start=\"7856\" data-end=\"7936\">\n<p data-start=\"7858\" data-end=\"7936\">\u25a1 Pack d\u2019audit : dossiers d\u2019acceptation, historique QA, \u00e9carts, actions correctives<\/p>\n<\/li>\n<li data-start=\"7937\" data-end=\"7998\">\n<p data-start=\"7939\" data-end=\"7998\">\u25a1 Contr\u00f4le de changement pour les \u00e9changes d\u2019affichage et les r\u00e9affectations de salles<\/p>\n<\/li>\n<li data-start=\"7999\" data-end=\"8066\">\n<p data-start=\"8001\" data-end=\"8066\">\u25a1 Politique de s\u00e9curit\u00e9 pour les terminaux distants (VPN\/SSO, moindre privil\u00e8ge)<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"8073\" data-end=\"8092\">Pack de d\u00e9marrage KPI<\/h2>\n<ul data-start=\"8094\" data-end=\"8408\">\n<li data-start=\"8094\" data-end=\"8148\">\n<p data-start=\"8096\" data-end=\"8148\"><strong data-start=\"8096\" data-end=\"8127\">% de la flotte dans la tol\u00e9rance<\/strong> (hebdomadaire\/trimestrielle)<\/p>\n<\/li>\n<li data-start=\"8149\" data-end=\"8196\">\n<p data-start=\"8151\" data-end=\"8196\"><strong data-start=\"8151\" data-end=\"8171\">D\u00e9rive moyenne \u0394L\/\u0394E<\/strong> depuis la derni\u00e8re calibration<\/p>\n<\/li>\n<li data-start=\"8197\" data-end=\"8242\">\n<p data-start=\"8199\" data-end=\"8242\"><strong data-start=\"8199\" data-end=\"8222\">D\u00e9lai de rem\u00e9diation<\/strong> pour les \u00e9checs de v\u00e9rification<\/p>\n<\/li>\n<li data-start=\"8243\" data-end=\"8298\">\n<p data-start=\"8245\" data-end=\"8298\"><strong data-start=\"8245\" data-end=\"8270\">Score de pr\u00e9paration \u00e0 l\u2019audit<\/strong> (compl\u00e9tude des dossiers)<\/p>\n<\/li>\n<li data-start=\"8299\" data-end=\"8349\">\n<p data-start=\"8301\" data-end=\"8349\"><strong data-start=\"8301\" data-end=\"8341\">Co\u00fbt par \u00e9cran calibr\u00e9 par an<\/strong> (TCO)<\/p>\n<\/li>\n<li data-start=\"8350\" data-end=\"8408\">\n<p data-start=\"8352\" data-end=\"8408\"><strong data-start=\"8352\" data-end=\"8377\">Indice de confiance des utilisateurs<\/strong> (enqu\u00eate radiologue\/clinicien)<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"8415\" data-end=\"8434\">Exemples de cas d\u2019utilisation<\/h2>\n<ul data-start=\"8436\" data-end=\"8870\">\n<li data-start=\"8436\" data-end=\"8547\">\n<p data-start=\"8438\" data-end=\"8547\"><strong data-start=\"8438\" data-end=\"8466\">Radiologie et mammographie :<\/strong> Cartographie GSDF, suivi de luminance, alertes d\u2019uniformit\u00e9, contr\u00f4les d\u2019ambiance en chambre noire.<\/p>\n<\/li>\n<li data-start=\"8548\" data-end=\"8651\">\n<p data-start=\"8550\" data-end=\"8651\"><strong data-start=\"8550\" data-end=\"8574\">Chirurgie et pathologie :<\/strong> Flux de travail <a href=\"https:\/\/hub.displaycal.net\/forums\/topic\/creating-3d-luts-from-icc-profiles\/\" target=\"_blank\" rel=\"noopener\">ICC\/3D-LUT<\/a> critiques en couleur et v\u00e9rification p\u00e9riodique des taches de couleur.<\/p>\n<\/li>\n<li data-start=\"8652\" data-end=\"8768\">\n<p data-start=\"8654\" data-end=\"8768\"><strong data-start=\"8654\" data-end=\"8686\">Unit\u00e9s d\u2019urgence et hospitalisation :<\/strong> Luminosit\u00e9 minimale \u00e0 l\u2019\u00e9chelle de la flotte et v\u00e9rifications rapides de constance pour r\u00e9duire la variabilit\u00e9.<\/p>\n<\/li>\n<li data-start=\"8769\" data-end=\"8870\">\n<p data-start=\"8771\" data-end=\"8870\"><strong data-start=\"8771\" data-end=\"8789\">T\u00e9l\u00e9radiologie :<\/strong> S\u00e9curisez des fen\u00eatres de contr\u00f4le qualit\u00e9 et de calibration \u00e0 distance qui ne perturbent pas les plannings des m\u00e9decins.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"8877\" data-end=\"8906\">Questions fr\u00e9quemment pos\u00e9es<\/h2>\n<p data-start=\"8908\" data-end=\"9103\"><strong data-start=\"8908\" data-end=\"8962\">Q : La calibration logicielle va-t-elle raccourcir la dur\u00e9e de vie de l\u2019\u00e9cran ?<\/strong><br data-start=\"8962\" data-end=\"8965\">R : Non. Il optimise la sortie selon les capacit\u00e9s de chaque panneau et met en \u00e9vidence les unit\u00e9s sous-performantes d\u00e8s le d\u00e9but, vous aidant \u00e0 rafra\u00eechir la situation en fonction des donn\u00e9es. <\/p>\n<p data-start=\"9105\" data-end=\"9276\"><strong data-start=\"9105\" data-end=\"9143\">Q : Avons-nous encore besoin d\u2019un colorim\u00e8tre ?<\/strong><br data-start=\"9143\" data-end=\"9146\">R : Oui \u2014 une sonde <strong data-start=\"9157\" data-end=\"9184\">standardis\u00e9e et soutenue<\/strong> pour l\u2019acceptation et des contr\u00f4les p\u00e9riodiques. Vous \u00e9liminez un tiroir rempli de pucks propri\u00e9taires. <\/p>\n<p data-start=\"9278\" data-end=\"9400\"><strong data-start=\"9278\" data-end=\"9314\">Q : Peut-on m\u00e9langer marques et mod\u00e8les ?<\/strong><br data-start=\"9314\" data-end=\"9317\">R : Absolument. C\u2019est un avantage cl\u00e9 : PerfectLum normalise l\u2019assurance qualit\u00e9 entre flottes mixtes. <\/p>\n<p data-start=\"9402\" data-end=\"9566\"><strong data-start=\"9402\" data-end=\"9434\">Q : Qu\u2019en est-il de la lumi\u00e8re ambiante ?<\/strong><br data-start=\"9434\" data-end=\"9437\">R : Vous \u00e9tablirez des politiques de chambre et utiliserez des alertes QA pour faire respecter la conformit\u00e9. Lorsque possible, ajoutez un contr\u00f4le de lumi\u00e8re, des stores ou un \u00e9clairage de travail. <\/p>\n<p data-start=\"9568\" data-end=\"9739\"><strong data-start=\"9568\" data-end=\"9614\">Q : Comment convaincre la direction clinique ?<\/strong><br data-start=\"9614\" data-end=\"9617\">R : Faites un pilote. Affichez les courbes avant\/apr\u00e8s GSDF, la r\u00e9duction de la d\u00e9rive et d\u00e9clarez les exportations. La qualit\u00e9 et le co\u00fbt parlent d\u2019eux-m\u00eames.  <\/p>\n<h2 data-start=\"9746\" data-end=\"9786\">D\u00e9buter : un manuel pratique<\/h2>\n<ol data-start=\"9788\" data-end=\"10161\">\n<li data-start=\"9788\" data-end=\"9863\">\n<p data-start=\"9791\" data-end=\"9863\"><strong data-start=\"9791\" data-end=\"9814\">Choisissez une cohorte pilote<\/strong> (10 \u00e0 20 affichages sur les modalit\u00e9s \u00e0 forte valeur).<\/p>\n<\/li>\n<li data-start=\"9864\" data-end=\"9938\">\n<p data-start=\"9867\" data-end=\"9938\"><strong data-start=\"9867\" data-end=\"9905\">D\u00e9ploie QUBYX OS Tools + PerfectLum<\/strong> et ton colorim\u00e8tre standard.<\/p>\n<\/li>\n<li data-start=\"9939\" data-end=\"9997\">\n<p data-start=\"9942\" data-end=\"9997\"><strong data-start=\"9942\" data-end=\"9963\">Calibrez en GSDF<\/strong> et activez les t\u00e2ches d\u2019assurance qualit\u00e9 automatis\u00e9es.<\/p>\n<\/li>\n<li data-start=\"9998\" data-end=\"10064\">\n<p data-start=\"10001\" data-end=\"10064\"><strong data-start=\"10001\" data-end=\"10015\">Suivez les KPI<\/strong> pendant 30 \u00e0 60 jours et recueillez les retours des cliniciens.<\/p>\n<\/li>\n<li data-start=\"10065\" data-end=\"10161\">\n<p data-start=\"10068\" data-end=\"10161\"><strong data-start=\"10068\" data-end=\"10087\">Ajustez par politique<\/strong> (mod\u00e8les, plannings, seuils), puis <strong data-start=\"10129\" data-end=\"10149\">institutionnalisez<\/strong> la gouvernance.<\/p>\n<\/li>\n<\/ol>\n<h2 data-start=\"10168\" data-end=\"10186\">La conclusion<\/h2>\n<p data-start=\"10188\" data-end=\"10494\">L\u2019\u00e9talonnage logiciel de QUBYX rend la <strong data-start=\"10229\" data-end=\"10257\">qualit\u00e9 de qualit\u00e9 diagnostique<\/strong> accessible sur une gamme plus large d\u2019\u00e9crans, avec <strong data-start=\"10306\" data-end=\"10319\">un TCO plus faible<\/strong>, <strong data-start=\"10321\" data-end=\"10343\">une conformit\u00e9 plus simple<\/strong> et <strong data-start=\"10349\" data-end=\"10370\">aucun verrouillage du fournisseur<\/strong>. Vous passerez moins de temps \u00e0 assurer la qualit\u00e9 des incendies et plus de temps \u00e0 fournir des images coh\u00e9rentes et fiables aux cliniciens et aux patients. <\/p>\n<p data-start=\"10188\" data-end=\"10494\">\n<h3 data-start=\"8543\" data-end=\"8565\"><strong data-start=\"8547\" data-end=\"8565\">Appel \u00e0 l\u2019action<\/strong><\/h3>\n<p data-start=\"8567\" data-end=\"8805\">D\u00e9couvrez les <strong data-start=\"8587\" data-end=\"8605\">outils QUBYX OS<\/strong> et <strong data-start=\"8610\" data-end=\"8630\">la suite PerfectLum<\/strong> \u2014 les solutions les plus avanc\u00e9es de logiciels de Claibration pour les environnements de radiologie, t\u00e9l\u00e9radiologie et imagerie clinique.<br data-start=\"8752\" data-end=\"8755\">Visitez <strong data-start=\"8761\" data-end=\"8803\"><a class=\"decorated-link cursor-pointer\" href=\"https:\/\/qubyx.com\/fr\/\" target=\"_new\" rel=\"noopener\" data-start=\"8763\" data-end=\"8801\">www.qubyx.com<\/a><\/strong><\/p>\n<p data-start=\"8567\" data-end=\"8805\">Pour garantir une pr\u00e9cision d\u2019affichage de qualit\u00e9 m\u00e9dicale tout en r\u00e9duisant les co\u00fbts r\u00e9currents du mat\u00e9riel propri\u00e9taire, la r\u00e9ponse est claire : passer d\u00e8s aujourd\u2019hui \u00e0 une <mark>plateforme logicielle d\u2019\u00e9talonnage <\/mark>comme <a href=\"https:\/\/qubyx.com\/qubyx-os-tools\/\"><b>QUBYX OS Tools<\/b><\/a> (Free) et <a href=\"https:\/\/qubyx.com\/products-perfectlum-4\/\"><b>PerfectLum<\/b><\/a> .<\/p>\n<p><b> <\/b><\/p>\n<p data-start=\"5644\" data-end=\"5884\"><strong>\u00c9tiquettes:<\/strong><\/p>\n<p data-start=\"5644\" data-end=\"5884\">DICOM Partie 14, \u00c9talonnage GSDF, QA d\u2019affichage hospitalier, QUBYX, logiciel d\u2019assurance qualit\u00e9 par imagerie m\u00e9dicale, PerfectLum, outils QUBYX OS, profil ICC, LUT 3D, QA t\u00e9l\u00e9radiologie, DIN 6868-157, AAPM TG18, AAPM TG270, \u00e9talonnage de moniteurs m\u00e9dicaux, gestion d\u2019affichage, r\u00e9duction des co\u00fbts informatiques en sant\u00e9.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Coupez le cordon : comment la calibration logicielle de QUBYX remplace le mat\u00e9riel co\u00fbteux dans la gestion de l\u2019affichage hospitalier [&hellip;]<\/p>\n","protected":false},"author":770,"featured_media":12471,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1250,1252,1251,1292],"tags":[1485,1296,1555,1651,1297,3374,1747,3696,3244,1614,1253,3695,2105,2299,1254,3697],"class_list":["post-12469","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actualites","category-logiciel-qubyx","category-perfectlum","category-qubyx-os","tag-3d-lut","tag-aapm-tg18","tag-aapm-tg270","tag-dicom-partie-14","tag-din-6868-157","tag-etalonnage-des-moniteurs-medicaux","tag-etalonnage-gsdf","tag-gestion-de-laffichage","tag-logiciel-dassurance-qualite-par-imagerie-medicale","tag-outils-qubyx-os","tag-parfait","tag-profil-icc","tag-qa-en-teleradiologie","tag-qa-sur-laffichage-hospitalier","tag-qubyx","tag-reduction-des-couts-informatiques-en-sante"],"acf":[],"_links":{"self":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts\/12469","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/users\/770"}],"replies":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/comments?post=12469"}],"version-history":[{"count":0,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts\/12469\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/media\/12471"}],"wp:attachment":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/media?parent=12469"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/categories?post=12469"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/tags?post=12469"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}