{"id":11835,"date":"2025-12-03T07:58:09","date_gmt":"2025-12-03T07:58:09","guid":{"rendered":"https:\/\/qubyx.com\/comment-construire-un-flux-de-travail-daffichage-en-radiologie-100-conforme-a-lassurance-qualite\/"},"modified":"2025-12-03T07:58:09","modified_gmt":"2025-12-03T07:58:09","slug":"comment-construire-un-flux-de-travail-daffichage-en-radiologie-100-conforme-a-lassurance-qualite","status":"publish","type":"post","link":"https:\/\/qubyx.com\/fr\/comment-construire-un-flux-de-travail-daffichage-en-radiologie-100-conforme-a-lassurance-qualite\/","title":{"rendered":"Comment construire un flux de travail d\u2019affichage en radiologie 100 % conforme \u00e0 l\u2019assurance qualit\u00e9"},"content":{"rendered":"<h2 style=\"text-align: center;\" data-start=\"194\" data-end=\"280\">Comment construire un flux de travail 100 % conforme au contr\u00f4le qualit\u00e9 des \u00e9crans de radiologie en 2026 et au-del\u00e0<\/h2>\n<p>&nbsp;<\/p>\n<p data-start=\"282\" data-end=\"523\">En 2026, la radiologie sera enti\u00e8rement num\u00e9rique, multi-sites et de plus en plus \u00e0 distance. Pourtant, une v\u00e9rit\u00e9 simple n\u2019a pas chang\u00e9 : <strong data-start=\"393\" data-end=\"470\">si vos affichages diagnostiques sont erron\u00e9s, tout ce qui se passe en aval peut \u00eatre faux<\/strong> \u2014 des fractures manqu\u00e9es aux l\u00e9sions subtiles des tissus mous. C\u2019est pourquoi <strong data-start=\"557\" data-end=\"574\">un flux de<\/strong> travail robuste et complet de conformit\u00e9 QA pour les affichages radiologiques n\u2019est plus optionnel. C\u2019est une n\u00e9cessit\u00e9 r\u00e9glementaire, clinique et m\u00e9dico-l\u00e9gale. La bonne nouvelle : vous n\u2019avez pas besoin de r\u00e9inventer la roue. Vous pouvez construire un flux de travail \u00e0 l\u2019avance en combinant les directives de <strong data-start=\"807\" data-end=\"820\">l\u2019AAPM TG18<\/strong>, <strong data-start=\"822\" data-end=\"836\">de l\u2019AAPM TG270<\/strong> et <strong data-start=\"842\" data-end=\"858\">du DIN 6868-157<\/strong> avec des outils modernes de <strong data-start=\"871\" data-end=\"898\">test de surveillance<\/strong> m\u00e9dicale et une automatisation.     <\/p>\n<p data-start=\"922\" data-end=\"956\">Dans ce guide, nous allons vous pr\u00e9senter :<\/p>\n<ul data-start=\"958\" data-end=\"1221\">\n<li data-start=\"958\" data-end=\"1023\">\n<p data-start=\"960\" data-end=\"1023\">Ce que signifie vraiment \u00ab conformit\u00e9 QA \u00e0 100 % \u00bb pour les affichages radiologiques<\/p>\n<\/li>\n<li data-start=\"1024\" data-end=\"1086\">\n<p data-start=\"1026\" data-end=\"1086\">Le r\u00f4le de <strong data-start=\"1038\" data-end=\"1051\">l\u2019AAPM TG18<\/strong>, <strong data-start=\"1053\" data-end=\"1062\">TG270<\/strong> et <strong data-start=\"1068\" data-end=\"1084\">DIN 6868-157<\/strong><\/p>\n<\/li>\n<li data-start=\"1087\" data-end=\"1149\">\n<p data-start=\"1089\" data-end=\"1149\">Un flux de travail \u00e9tape par \u00e9tape que vous pourrez mettre en place \u00e0 partir de 2026<\/p>\n<\/li>\n<li data-start=\"1150\" data-end=\"1221\">\n<p data-start=\"1152\" data-end=\"1221\">Comment automatiser, documenter et am\u00e9liorer continuellement votre programme QA<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"1228\" data-end=\"1279\">1. Que signifie r\u00e9ellement \u00ab conformit\u00e9 QA \u00e0 100 % \u00bb ?<\/h2>\n<p data-start=\"1281\" data-end=\"1364\">\u00ab Conformit\u00e9 QA \u00e0 100 % \u00bb ne signifie pas que vos \u00e9crans sont parfaits en permanence. Cela signifie : <\/p>\n<ol data-start=\"1366\" data-end=\"2320\">\n<li data-start=\"1366\" data-end=\"1476\">\n<p data-start=\"1369\" data-end=\"1476\"><strong data-start=\"1369\" data-end=\"1417\">Tous les tests requis sont d\u00e9finis et programm\u00e9s<\/strong> (acceptation, constance, contr\u00f4les visuels et quantitatifs).<\/p>\n<\/li>\n<li data-start=\"1477\" data-end=\"1601\">\n<p data-start=\"1480\" data-end=\"1601\"><strong data-start=\"1480\" data-end=\"1530\">Chaque test est effectu\u00e9 \u00e0 l\u2019intervalle correct<\/strong> (quotidien, mensuel, annuel, etc.).<\/p>\n<\/li>\n<li data-start=\"1602\" data-end=\"1680\">\n<p data-start=\"1605\" data-end=\"1680\"><strong data-start=\"1605\" data-end=\"1645\">Les r\u00e9sultats sont document\u00e9s et tra\u00e7ables<\/strong> pour les audits et les revues d\u2019incidents.<\/p>\n<\/li>\n<li data-start=\"1681\" data-end=\"1794\">\n<p data-start=\"1684\" data-end=\"1794\"><strong data-start=\"1684\" data-end=\"1720\">Les non-conformit\u00e9s d\u00e9clenchent des actions<\/strong> (service, recalibrage, remplacement du moniteur) dans des d\u00e9lais d\u00e9finis.<\/p>\n<\/li>\n<li data-start=\"1795\" data-end=\"2320\">\n<p data-start=\"1798\" data-end=\"1873\"><strong data-start=\"1798\" data-end=\"1863\">Votre processus est conforme aux normes et r\u00e9glementations reconnues<\/strong>, telles que :<\/p>\n<ul data-start=\"1877\" data-end=\"2320\">\n<li data-start=\"1877\" data-end=\"2014\">\n<p data-start=\"1879\" data-end=\"2014\"><strong data-start=\"1879\" data-end=\"1892\">AAPM TG18<\/strong> \u2013 lignes directrices classiques pour l\u2019\u00e9valuation des performances d\u2019affichage et des sch\u00e9mas de test TG18.<\/p>\n<\/li>\n<li data-start=\"2018\" data-end=\"2154\">\n<p data-start=\"2020\" data-end=\"2154\"><strong data-start=\"2020\" data-end=\"2034\">AAPM TG270<\/strong> \u2013 cadre mis \u00e0 jour pour l\u2019assurance qualit\u00e9 des \u00e9crans plats modernes.<\/p>\n<\/li>\n<li data-start=\"2158\" data-end=\"2320\">\n<p data-start=\"2160\" data-end=\"2320\"><strong data-start=\"2160\" data-end=\"2176\">DIN 6868-157<\/strong> \u2013 norme allemande \/ europ\u00e9enne pour les tests d\u2019acceptation et de constance des syst\u00e8mes d\u2019affichage d\u2019images diagnostiques.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p data-start=\"2322\" data-end=\"2518\">Si vous pouvez <strong data-start=\"2333\" data-end=\"2341\">d\u00e9montrer<\/strong> \u2014 avec des journaux et des rapports \u2014 que votre flux de travail r\u00e9pond continuellement \u00e0 ces crit\u00e8res, vous \u00eates en position solide pour <strong data-start=\"2450\" data-end=\"2469\">2026 et au-del\u00e0<\/strong>, m\u00eame avec l\u2019\u00e9volution des affichages, des PACS et des r\u00e9glementations.<\/p>\n<h2 data-start=\"2525\" data-end=\"2593\">2. Les normes : TG18, TG270 et DIN 6868-157 en langage clair<\/h2>\n<h3 data-start=\"2595\" data-end=\"2634\">AAPM TG18 \u2013 Le \u00ab Manuel de Jeux Original \u00bb<\/h3>\n<p data-start=\"2636\" data-end=\"2744\"><strong data-start=\"2636\" data-end=\"2649\">AAPM TG18<\/strong> se concentre sur <strong data-start=\"2661\" data-end=\"2716\">la mani\u00e8re d\u2019\u00e9valuer la performance des affichages m\u00e9dicaux<\/strong> sur le terrain. Il d\u00e9crit : <\/p>\n<ul data-start=\"2746\" data-end=\"3028\">\n<li data-start=\"2746\" data-end=\"2795\">\n<p data-start=\"2748\" data-end=\"2795\">Utilisation des <strong data-start=\"2755\" data-end=\"2777\">sch\u00e9mas de test TG18<\/strong> (par exemple, TG18-QC)<\/p>\n<\/li>\n<li data-start=\"2796\" data-end=\"3028\">\n<p data-start=\"2798\" data-end=\"2832\">Tests visuels et quantitatifs pour :<\/p>\n<ul data-start=\"2835\" data-end=\"3028\">\n<li data-start=\"2835\" data-end=\"2867\">\n<p data-start=\"2837\" data-end=\"2867\">Luminance, r\u00e9ponse au contraste<\/p>\n<\/li>\n<li data-start=\"2870\" data-end=\"2894\">\n<p data-start=\"2872\" data-end=\"2894\">Distorsion g\u00e9om\u00e9trique<\/p>\n<\/li>\n<li data-start=\"2897\" data-end=\"2925\">\n<p data-start=\"2899\" data-end=\"2925\">Reflet, bruit, \u00e9blouissement<\/p>\n<\/li>\n<li data-start=\"2928\" data-end=\"2975\">\n<p data-start=\"2930\" data-end=\"2975\">D\u00e9pendance spatiale et angulaire de la luminance<\/p>\n<\/li>\n<li data-start=\"2978\" data-end=\"3028\">\n<p data-start=\"2980\" data-end=\"3028\">Artefacts<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p data-start=\"3030\" data-end=\"3148\">TG18 est encore largement r\u00e9f\u00e9renc\u00e9e, notamment pour <strong data-start=\"3078\" data-end=\"3100\">les sch\u00e9mas visuels de contr\u00f4le qualit\u00e9<\/strong> et les routines de <strong data-start=\"3111\" data-end=\"3138\">test de base des moniteurs m\u00e9dicaux<\/strong> .<\/p>\n<h3 data-start=\"3150\" data-end=\"3200\">AAPM TG270 \u2013 <strong data-start=\"557\" data-end=\"574\">Conformit\u00e9 moderne au contr\u00f4le qualit\u00e9<\/strong> des \u00e9crans plats<\/h3>\n<p data-start=\"3202\" data-end=\"3420\">Publi\u00e9 en 2019 et activement discut\u00e9 jusqu\u2019en 2025, <strong data-start=\"3257\" data-end=\"3271\">l\u2019AAPM TG270<\/strong> met \u00e0 jour et \u00e9tend le TG18 pour la technologie d\u2019affichage actuelle (LCD, OLED, panneaux multi-r\u00e9solution). Il se concentre sur : <\/p>\n<ul data-start=\"3422\" data-end=\"3683\">\n<li data-start=\"3422\" data-end=\"3491\">\n<p data-start=\"3424\" data-end=\"3491\">Un <strong data-start=\"3426\" data-end=\"3451\">programme structur\u00e9 de conformit\u00e9 QA<\/strong> avec des types de tests et des fr\u00e9quences clairs<\/p>\n<\/li>\n<li data-start=\"3492\" data-end=\"3537\">\n<p data-start=\"3494\" data-end=\"3537\">Nouveaux mod\u00e8les de test et mod\u00e8les r\u00e9vis\u00e9s (sQC \/ pQC)<\/p>\n<\/li>\n<li data-start=\"3538\" data-end=\"3617\">\n<p data-start=\"3540\" data-end=\"3617\">Crit\u00e8res de performance mis \u00e0 jour pour la luminance, le contraste, l\u2019uniformit\u00e9 et la couleur<\/p>\n<\/li>\n<li data-start=\"3618\" data-end=\"3683\">\n<p data-start=\"3620\" data-end=\"3683\">Harmonisation avec DICOM Partie 14 GSDF et flux de travail pratiques<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3685\" data-end=\"3765\">En r\u00e9sum\u00e9 : TG270 est votre <strong data-start=\"3709\" data-end=\"3732\">plan strat\u00e9gique<\/strong> pour un programme moderne de contr\u00f4le qualit\u00e9 d\u2019affichage.<\/p>\n<h3 data-start=\"3767\" data-end=\"3826\">DIN 6868-157 \u2013 Acceptation et tests de constance en Europe<\/h3>\n<p data-start=\"3828\" data-end=\"4001\"><strong data-start=\"3828\" data-end=\"3849\">Le DIN 6868-157:2014<\/strong>, mis \u00e0 jour sous <strong data-start=\"3862\" data-end=\"3883\">le DIN 6868-157:2022<\/strong>, d\u00e9finit les tests d\u2019acceptation et de constance pour les syst\u00e8mes d\u2019affichage d\u2019images de diagnostic :<\/p>\n<ul data-start=\"4003\" data-end=\"4363\">\n<li data-start=\"4003\" data-end=\"4107\">\n<p data-start=\"4005\" data-end=\"4107\">Cela s\u2019applique aux <strong data-start=\"4025\" data-end=\"4050\">syst\u00e8mes d\u2019affichage d\u2019images<\/strong> complets (moniteur + poste de travail + logiciel), pas seulement au panneau<\/p>\n<\/li>\n<li data-start=\"4108\" data-end=\"4363\">\n<p data-start=\"4110\" data-end=\"4120\">Sp\u00e9cifie :<\/p>\n<ul data-start=\"4123\" data-end=\"4363\">\n<li data-start=\"4123\" data-end=\"4226\">\n<p data-start=\"4125\" data-end=\"4226\">param\u00e8tres <strong data-start=\"4125\" data-end=\"4144\">de test<\/strong> (luminance, contraste, homog\u00e9n\u00e9it\u00e9, r\u00e9solution spatiale, luminance voilante, etc.)<\/p>\n<\/li>\n<li data-start=\"4229\" data-end=\"4299\">\n<p data-start=\"4231\" data-end=\"4299\"><strong data-start=\"4231\" data-end=\"4247\">Valeurs limites<\/strong> (luminance maximale minimale, rapport de contraste, etc.)<\/p>\n<\/li>\n<li data-start=\"4302\" data-end=\"4363\">\n<p data-start=\"4304\" data-end=\"4363\"><strong data-start=\"4304\" data-end=\"4322\">Intervalles de test<\/strong> (acceptation, tests de constance p\u00e9riodique)<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p data-start=\"4365\" data-end=\"4500\">Si vous op\u00e9rez dans l\u2019UE ou servez des clients t\u00e9l\u00e9radiologiques transfrontaliers, <strong data-start=\"4435\" data-end=\"4453\">la conformit\u00e9 DIN<\/strong> repr\u00e9sente un avantage concurrentiel et r\u00e9glementaire important.<\/p>\n<h2 data-start=\"4507\" data-end=\"4571\">3. Fondation : D\u00e9finissez votre inventaire d\u2019affichage et vos classes de risque<\/h2>\n<p data-start=\"4573\" data-end=\"4633\">Avant m\u00eame de lancer un motif de test, il faut <strong data-start=\"4618\" data-end=\"4632\">de la visibilit\u00e9<\/strong> possible.<\/p>\n<ol data-start=\"4635\" data-end=\"5427\">\n<li data-start=\"4635\" data-end=\"4866\">\n<p data-start=\"4638\" data-end=\"4665\"><strong data-start=\"4638\" data-end=\"4664\">Inventez tous les pr\u00e9sentoirs<\/strong> :<\/p>\n<ul data-start=\"4669\" data-end=\"4866\">\n<li data-start=\"4669\" data-end=\"4701\">\n<p data-start=\"4671\" data-end=\"4701\">Stations de travail de diagnostic PACS<\/p>\n<\/li>\n<li data-start=\"4705\" data-end=\"4752\">\n<p data-start=\"4707\" data-end=\"4752\">Affichages de mamographie \/ tomosynth\u00e8se mammaire<\/p>\n<\/li>\n<li data-start=\"4756\" data-end=\"4781\">\n<p data-start=\"4758\" data-end=\"4781\">Consoles CT \/ MR \/ US<\/p>\n<\/li>\n<li data-start=\"4785\" data-end=\"4821\">\n<p data-start=\"4787\" data-end=\"4821\">Postes de r\u00e9vision (urgences, soins intensifs, services)<\/p>\n<\/li>\n<li data-start=\"4825\" data-end=\"4866\">\n<p data-start=\"4827\" data-end=\"4866\">Installations de radiologues \u00e0 domicile \u00e0 distance<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"4868\" data-end=\"5188\">\n<p data-start=\"4871\" data-end=\"4980\"><strong data-start=\"4871\" data-end=\"4904\">Classifier par risque et cas d\u2019usage<\/strong> (inspir\u00e9 par TG270 &amp; DIN 6868-157) :<\/p>\n<ul data-start=\"4984\" data-end=\"5188\">\n<li data-start=\"4984\" data-end=\"5046\">\n<p data-start=\"4986\" data-end=\"5046\"><strong data-start=\"4986\" data-end=\"5008\">Diagnostic primaire<\/strong> (par exemple, station de lecture radiologue)<\/p>\n<\/li>\n<li data-start=\"5050\" data-end=\"5101\">\n<p data-start=\"5052\" data-end=\"5101\"><strong data-start=\"5052\" data-end=\"5089\">Revue proche du diagnostic \/ clinique<\/strong> (urgences, r\u00e9animation)<\/p>\n<\/li>\n<li data-start=\"5105\" data-end=\"5145\">\n<p data-start=\"5107\" data-end=\"5145\"><strong data-start=\"5107\" data-end=\"5143\">Consoles Technologues \/ modalit\u00e9s<\/strong><\/p>\n<\/li>\n<li data-start=\"5149\" data-end=\"5188\">\n<p data-start=\"5151\" data-end=\"5188\"><strong data-start=\"5151\" data-end=\"5186\">Administratif \/ non diagnostique<\/strong><\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"5190\" data-end=\"5427\">\n<p data-start=\"5193\" data-end=\"5246\">D\u00e9finissez <strong data-start=\"5200\" data-end=\"5235\">les exigences de performance et de conformit\u00e9 QA<\/strong> par classe :<\/p>\n<ul data-start=\"5250\" data-end=\"5427\">\n<li data-start=\"5250\" data-end=\"5341\">\n<p data-start=\"5252\" data-end=\"5341\">Luminance plus \u00e9lev\u00e9e, uniformit\u00e9 plus stricte et tests plus fr\u00e9quents pour les <strong data-start=\"5319\" data-end=\"5330\">\u00e9crans primaires<\/strong><\/p>\n<\/li>\n<li data-start=\"5345\" data-end=\"5427\">\n<p data-start=\"5347\" data-end=\"5427\">Des limites moins strictes et des intervalles plus longs pour <strong data-start=\"5391\" data-end=\"5416\">les affichages de revue \/ de technicien<\/strong><\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p data-start=\"5429\" data-end=\"5572\">Cette classification bas\u00e9e sur le risque est essentielle \u00e0 une strat\u00e9gie <strong data-start=\"5472\" data-end=\"5504\">de conformit\u00e9 QA rentable<\/strong> : vous appliquez la plus grande intensit\u00e9 l\u00e0 o\u00f9 la d\u00e9faillance fait le plus mal.<\/p>\n<h2 data-start=\"5579\" data-end=\"5632\">4. \u00c9tablir un planning QA pr\u00eat pour 2026 (quotidien \u2192 annuel)<\/h2>\n<p data-start=\"5634\" data-end=\"5761\">Utilisez les directives TG18\/TG270\/DIN ainsi que vos r\u00e9glementations locales pour d\u00e9finir un <strong data-start=\"5702\" data-end=\"5721\">planning \u00e0 niveaux<\/strong>.<\/p>\n<h3 data-start=\"5763\" data-end=\"5826\">4.1 Contr\u00f4les quotidiens \/ par service (Radiologues et Technologues)<\/h3>\n<p data-start=\"5828\" data-end=\"5896\">But : <strong data-start=\"5834\" data-end=\"5854\">Gardien rapide<\/strong> \u2014 d\u00e9tecte les probl\u00e8mes \u00e9vidents avant une blessure du patient.<\/p>\n<ul data-start=\"5898\" data-end=\"6310\">\n<li data-start=\"5898\" data-end=\"6075\">\n<p data-start=\"5900\" data-end=\"5945\"><strong data-start=\"5900\" data-end=\"5944\">V\u00e9rification visuelle du pattern TG18-QC \/ TG270-sQC<\/strong> :<\/p>\n<ul data-start=\"5948\" data-end=\"6075\">\n<li data-start=\"5948\" data-end=\"6017\">\n<p data-start=\"5950\" data-end=\"6017\">V\u00e9rifiez les pas en niveaux de gris, les patchs de contraste et les objets de test centraux<\/p>\n<\/li>\n<li data-start=\"6020\" data-end=\"6075\">\n<p data-start=\"6022\" data-end=\"6075\">Confirmez que le texte et les petits d\u00e9tails sont clairement visibles<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6076\" data-end=\"6142\">\n<p data-start=\"6078\" data-end=\"6142\"><strong data-start=\"6078\" data-end=\"6104\">V\u00e9rification rapide DICOM GSDF<\/strong> \u00e0 l\u2019aide d\u2019outils ou logiciels QA int\u00e9gr\u00e9s<\/p>\n<\/li>\n<li data-start=\"6143\" data-end=\"6253\">\n<p data-start=\"6145\" data-end=\"6177\"><strong data-start=\"6145\" data-end=\"6176\">Lumi\u00e8re ambiante \/ reflets<\/strong> :<\/p>\n<ul data-start=\"6180\" data-end=\"6253\">\n<li data-start=\"6180\" data-end=\"6253\">\n<p data-start=\"6182\" data-end=\"6253\">V\u00e9rifiez que les stores et les lumi\u00e8res de la pi\u00e8ce sont dans la configuration normale de lecture<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6254\" data-end=\"6310\">\n<p data-start=\"6256\" data-end=\"6310\"><strong data-start=\"6256\" data-end=\"6290\">Documentation simple de r\u00e9ussite\/\u00e9chec<\/strong> dans votre syst\u00e8me <strong data-start=\"557\" data-end=\"574\">de conformit\u00e9 QA<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"6312\" data-end=\"6370\">4.2 <strong data-start=\"557\" data-end=\"574\">Conformit\u00e9<\/strong> technique QA mensuelle \/ trimestrielle (physique m\u00e9dicale)<\/h3>\n<p data-start=\"6372\" data-end=\"6429\">Objectif : <strong data-start=\"6378\" data-end=\"6405\">Validation quantitative<\/strong> de la performance d\u2019affichage.<\/p>\n<ul data-start=\"6431\" data-end=\"6894\">\n<li data-start=\"6431\" data-end=\"6589\">\n<p data-start=\"6433\" data-end=\"6469\"><strong data-start=\"6433\" data-end=\"6468\">Luminance et r\u00e9ponse au contraste<\/strong> :<\/p>\n<ul data-start=\"6472\" data-end=\"6589\">\n<li data-start=\"6472\" data-end=\"6589\">\n<p data-start=\"6474\" data-end=\"6589\">Mesurer <strong data-start=\"6482\" data-end=\"6512\">Lmax, Lmin, rapport de contraste<\/strong> et conformit\u00e9 aux GSDF (DICOM Part 14).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"6590\" data-end=\"6637\">\n<p data-start=\"6592\" data-end=\"6637\"><strong data-start=\"6592\" data-end=\"6616\">Uniformit\u00e9 de luminance<\/strong> sur tout l\u2019\u00e9cran<\/p>\n<\/li>\n<li data-start=\"6638\" data-end=\"6700\">\n<p data-start=\"6640\" data-end=\"6700\"><strong data-start=\"6640\" data-end=\"6669\">V\u00e9rifications de r\u00e9solution et de bruit<\/strong> utilisant les motifs TG18 ou TG270<\/p>\n<\/li>\n<li data-start=\"6701\" data-end=\"6772\">\n<p data-start=\"6703\" data-end=\"6772\"><strong data-start=\"6703\" data-end=\"6729\">Couleur et chromaticit\u00e9<\/strong> (pour les flux de travail couleur et l\u2019imagerie fusionnelle)<\/p>\n<\/li>\n<li data-start=\"6773\" data-end=\"6894\">\n<p data-start=\"6775\" data-end=\"6894\"><strong data-start=\"6775\" data-end=\"6812\">Voilement luminant \/ lumi\u00e8re ambiante<\/strong> (DIN 6868-157 n\u00e9cessite des limites sp\u00e9cifiques).<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"6896\" data-end=\"6932\">4.3 Annuel \/ Apr\u00e8s des changements majeurs<\/h3>\n<p data-start=\"6934\" data-end=\"6999\">Objectif : <strong data-start=\"6940\" data-end=\"6976\">acceptation compl\u00e8te ou r\u00e9acceptation<\/strong> du syst\u00e8me d\u2019affichage.<\/p>\n<ul data-start=\"7001\" data-end=\"7349\">\n<li data-start=\"7001\" data-end=\"7072\">\n<p data-start=\"7003\" data-end=\"7072\"><strong data-start=\"7012\" data-end=\"7061\">Test d\u2019acceptation complet selon les crit\u00e8res DIN 6868-157 ou TG270<\/strong><\/p>\n<\/li>\n<li data-start=\"7073\" data-end=\"7262\">\n<p data-start=\"7075\" data-end=\"7091\">V\u00e9rification de :<\/p>\n<ul data-start=\"7094\" data-end=\"7262\">\n<li data-start=\"7094\" data-end=\"7114\">\n<p data-start=\"7096\" data-end=\"7114\">\u00c9talonnage GSDF<\/p>\n<\/li>\n<li data-start=\"7117\" data-end=\"7153\">\n<p data-start=\"7119\" data-end=\"7153\">R\u00e9solution spatiale, motifs MTF<\/p>\n<\/li>\n<li data-start=\"7156\" data-end=\"7180\">\n<p data-start=\"7158\" data-end=\"7180\">Distorsion g\u00e9om\u00e9trique<\/p>\n<\/li>\n<li data-start=\"7183\" data-end=\"7214\">\n<p data-start=\"7185\" data-end=\"7214\">D\u00e9fauts et artefacts de pixels<\/p>\n<\/li>\n<li data-start=\"7217\" data-end=\"7262\">\n<p data-start=\"7219\" data-end=\"7262\">Pr\u00e9cision des couleurs (pour un usage diagnostique des couleurs)<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"7263\" data-end=\"7349\">\n<p data-start=\"7265\" data-end=\"7349\">Assurez-vous que <strong data-start=\"7272\" data-end=\"7304\">la documentation est pr\u00eate \u00e0 l\u2019audit<\/strong> et correspondante aux exigences r\u00e9glementaires locales.<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"7356\" data-end=\"7405\">5. \u00c9tape par \u00e9tape : un flux de travail de conformit\u00e9 100 % QA<\/h2>\n<p data-start=\"7407\" data-end=\"7506\">Voici un flux de travail pratique et complet que vous pouvez mettre en \u0153uvre d\u00e8s maintenant et sur lequel vous pouvez toujours compter en 2026 et au-del\u00e0.<\/p>\n<h3 data-start=\"7508\" data-end=\"7539\">\u00c9tape 1 \u2013 Gouvernance et r\u00f4les<\/h3>\n<ul data-start=\"7541\" data-end=\"7886\">\n<li data-start=\"7541\" data-end=\"7632\">\n<p data-start=\"7543\" data-end=\"7632\">Nommez un <strong data-start=\"7553\" data-end=\"7572\">responsable QA d\u2019affichage<\/strong> (g\u00e9n\u00e9ralement un physicien m\u00e9dical ou un ing\u00e9nieur principal en imagerie).<\/p>\n<\/li>\n<li data-start=\"7633\" data-end=\"7886\">\n<p data-start=\"7635\" data-end=\"7663\">D\u00e9finissez les responsabilit\u00e9s pour :<\/p>\n<ul data-start=\"7666\" data-end=\"7886\">\n<li data-start=\"7666\" data-end=\"7716\">\n<p data-start=\"7668\" data-end=\"7716\"><strong data-start=\"7668\" data-end=\"7691\">Contr\u00f4les visuels quotidiens<\/strong> (radiologues \/ techniciens)<\/p>\n<\/li>\n<li data-start=\"7719\" data-end=\"7764\">\n<p data-start=\"7721\" data-end=\"7764\"><strong data-start=\"7721\" data-end=\"7752\">Tests quantitatifs p\u00e9riodiques<\/strong> (physique)<\/p>\n<\/li>\n<li data-start=\"7767\" data-end=\"7886\">\n<p data-start=\"7769\" data-end=\"7886\"><strong data-start=\"7769\" data-end=\"7807\">Actions correctives et escalades<\/strong> (IT, fournisseur, g\u00e9nie biom\u00e9dical).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3 data-start=\"7888\" data-end=\"7934\">\u00c9tape 2 \u2013 Standardiser les outils et les mod\u00e8les de test<\/h3>\n<ul data-start=\"7936\" data-end=\"8225\">\n<li data-start=\"7936\" data-end=\"8146\">\n<p data-start=\"7938\" data-end=\"7986\">Choisissez une <strong data-start=\"7947\" data-end=\"7971\"> plateforme logicielle<\/strong> <strong data-start=\"557\" data-end=\"574\">de conformit\u00e9 QA<\/strong> qui prend en charge :<\/p>\n<ul data-start=\"7989\" data-end=\"8146\">\n<li data-start=\"7989\" data-end=\"8024\">\n<p data-start=\"7991\" data-end=\"8024\">Patrons de test TG18 et\/ou TG270<\/p>\n<\/li>\n<li data-start=\"8027\" data-end=\"8068\">\n<p data-start=\"8029\" data-end=\"8068\">Flux de travail de test de constance DIN 6868-157<\/p>\n<\/li>\n<li data-start=\"8071\" data-end=\"8106\">\n<p data-start=\"8073\" data-end=\"8106\">V\u00e9rification DICOM Partie 14 GSDF<\/p>\n<\/li>\n<li data-start=\"8109\" data-end=\"8146\">\n<p data-start=\"8111\" data-end=\"8146\">Journalisation et rapports centralis\u00e9s<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"8147\" data-end=\"8225\">\n<p data-start=\"8149\" data-end=\"8225\">Standardisez les <strong data-start=\"8164\" data-end=\"8195\">luminim\u00e8tres calibr\u00e9s<\/strong> et les instructions d\u2019utilisation claires.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"8227\" data-end=\"8282\">\u00c9tape 3 \u2013 Configurer les mod\u00e8les de test par classe d\u2019affichage<\/h3>\n<p data-start=\"8284\" data-end=\"8334\">Pour chaque classe d\u2019affichage (principale, test, console) :<\/p>\n<ul data-start=\"8336\" data-end=\"8699\">\n<li data-start=\"8336\" data-end=\"8423\">\n<p data-start=\"8338\" data-end=\"8423\">D\u00e9finissez <strong data-start=\"8345\" data-end=\"8360\">quels tests<\/strong> s\u2019appliquent (visuel, luminance, uniformit\u00e9, couleur, ambiance, etc.).<\/p>\n<\/li>\n<li data-start=\"8424\" data-end=\"8552\">\n<p data-start=\"8426\" data-end=\"8552\">D\u00e9finissez <strong data-start=\"8430\" data-end=\"8448\">la fr\u00e9quence de test<\/strong> en fonction des directives TG270 et DIN, ainsi que votre propre \u00e9valuation des risques.<\/p>\n<\/li>\n<li data-start=\"8553\" data-end=\"8699\">\n<p data-start=\"8555\" data-end=\"8588\">Sp\u00e9cifiez <strong data-start=\"8563\" data-end=\"8587\">les seuils de r\u00e9ussite\/\u00e9chec<\/strong> :<\/p>\n<ul data-start=\"8591\" data-end=\"8699\">\n<li data-start=\"8591\" data-end=\"8612\">\n<p data-start=\"8593\" data-end=\"8612\">Luminance minimale<\/p>\n<\/li>\n<li data-start=\"8615\" data-end=\"8633\">\n<p data-start=\"8617\" data-end=\"8633\">Rapport de contraste<\/p>\n<\/li>\n<li data-start=\"8636\" data-end=\"8662\">\n<p data-start=\"8638\" data-end=\"8662\">Non-uniformit\u00e9 maximale<\/p>\n<\/li>\n<li data-start=\"8665\" data-end=\"8699\">\n<p data-start=\"8667\" data-end=\"8699\">Nombre maximal de pixels d\u00e9fectueux<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3 data-start=\"8701\" data-end=\"8747\">\u00c9tape 4 \u2013 Automatiser la planification et les rappels<\/h3>\n<p data-start=\"8749\" data-end=\"8810\">Les programmes QA 2026+ ne devraient pas d\u00e9pendre de post-its et de m\u00e9moire.<\/p>\n<ul data-start=\"8812\" data-end=\"9013\">\n<li data-start=\"8812\" data-end=\"9013\">\n<p data-start=\"8814\" data-end=\"8846\">Utilisez votre logiciel <strong data-start=\"557\" data-end=\"574\">de conformit\u00e9 QA<\/strong> ou CMMS pour :<\/p>\n<ul data-start=\"8849\" data-end=\"9013\">\n<li data-start=\"8849\" data-end=\"8911\">\n<p data-start=\"8851\" data-end=\"8911\">G\u00e9n\u00e9rez <strong data-start=\"8865\" data-end=\"8909\">automatiquement des t\u00e2ches quotidiennes, hebdomadaires, mensuelles et annuelles<\/strong><\/p>\n<\/li>\n<li data-start=\"8914\" data-end=\"8957\">\n<p data-start=\"8916\" data-end=\"8957\">Attribuer des t\u00e2ches \u00e0 des r\u00f4les ou utilisateurs sp\u00e9cifiques<\/p>\n<\/li>\n<li data-start=\"8960\" data-end=\"9013\">\n<p data-start=\"8962\" data-end=\"9013\"><strong data-start=\"8970\" data-end=\"8980\">Alertes<\/strong> d\u00e9clencheuses lorsque les tests sont en retard ou \u00e9chouent<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3 data-start=\"9015\" data-end=\"9053\">\u00c9tape 5 \u2013 Ex\u00e9cuter, R\u00e9viser, Escalader<\/h3>\n<p data-start=\"9055\" data-end=\"9075\">Pour chaque \u00e9preuve test :<\/p>\n<ol data-start=\"9077\" data-end=\"9484\">\n<li data-start=\"9077\" data-end=\"9165\">\n<p data-start=\"9080\" data-end=\"9165\"><strong data-start=\"9080\" data-end=\"9100\">Effectuez le test<\/strong> (visuel ou quantitatif) en utilisant le sch\u00e9ma et la m\u00e9thode d\u00e9finis.<\/p>\n<\/li>\n<li data-start=\"9166\" data-end=\"9291\">\n<p data-start=\"9169\" data-end=\"9185\"><strong data-start=\"9169\" data-end=\"9184\">R\u00e9sultats du journal<\/strong> :<\/p>\n<ul data-start=\"9189\" data-end=\"9291\">\n<li data-start=\"9189\" data-end=\"9237\">\n<p data-start=\"9191\" data-end=\"9237\">Num\u00e9rique (par exemple, Lmax, Lmin, % de non-uniformit\u00e9)<\/p>\n<\/li>\n<li data-start=\"9241\" data-end=\"9261\">\n<p data-start=\"9243\" data-end=\"9261\">R\u00e9sultat r\u00e9ussi\/\u00e9chec<\/p>\n<\/li>\n<li data-start=\"9265\" data-end=\"9291\">\n<p data-start=\"9267\" data-end=\"9291\">Op\u00e9rateur et horodatage<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"9292\" data-end=\"9484\">\n<p data-start=\"9295\" data-end=\"9331\">Si un param\u00e8tre d\u00e9passe les seuils :<\/p>\n<ul data-start=\"9335\" data-end=\"9484\">\n<li data-start=\"9335\" data-end=\"9402\">\n<p data-start=\"9337\" data-end=\"9402\"><strong data-start=\"9337\" data-end=\"9357\">Signalez l\u2019affichage<\/strong> (par exemple, \u00ab Ne pas utiliser pour le diagnostic primaire \u00bb)<\/p>\n<\/li>\n<li data-start=\"9406\" data-end=\"9484\">\n<p data-start=\"9408\" data-end=\"9484\">Cr\u00e9ez une <strong data-start=\"9417\" data-end=\"9438\">action corrective<\/strong> (appel de service, recalibrage, remplacement).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h3 data-start=\"9486\" data-end=\"9538\">\u00c9tape 6 \u2013 Analyse des tendances et am\u00e9lioration continue<\/h3>\n<p data-start=\"9540\" data-end=\"9586\">Une fois que vous disposez de quelques mois de donn\u00e9es, utilisez-les pour :<\/p>\n<ul data-start=\"9588\" data-end=\"9913\">\n<li data-start=\"9588\" data-end=\"9710\">\n<p data-start=\"9590\" data-end=\"9710\"><strong data-start=\"9590\" data-end=\"9630\">La luminance et l\u2019uniformit\u00e9 des tendances d\u00e9rivent<\/strong> avec le temps (les mod\u00e8les de d\u00e9faillance localis\u00e9e pr\u00e9cocement).<\/p>\n<\/li>\n<li data-start=\"9711\" data-end=\"9815\">\n<p data-start=\"9713\" data-end=\"9815\"><strong data-start=\"9722\" data-end=\"9740\">Optimiser les intervalles de test<\/strong> (par exemple, raccourcir pour les moniteurs instables, allonger pour les unit\u00e9s tr\u00e8s stables).<\/p>\n<\/li>\n<li data-start=\"9816\" data-end=\"9913\">\n<p data-start=\"9818\" data-end=\"9913\">Informez <strong data-start=\"9825\" data-end=\"9840\">les achats<\/strong> avec de vraies donn\u00e9es de performance (quelles marques\/mod\u00e8les restent plus longtemps dans les sp\u00e9cifications ?).<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"9915\" data-end=\"10017\">Cela transforme la conformit\u00e9 QA d\u2019un exercice \u00e0 cocher en une <strong data-start=\"9977\" data-end=\"10016\">boucle d\u2019am\u00e9lioration continue de la qualit\u00e9<\/strong>.<\/p>\n<h2 data-start=\"10024\" data-end=\"10081\">6. Conseils pratiques pour les tests de moniteurs m\u00e9dicaux en 2026+<\/h2>\n<h3 data-start=\"10083\" data-end=\"10132\">6.1 Ne pas ignorer la lecture \u00e0 domicile et \u00e0 distance<\/h3>\n<p data-start=\"10134\" data-end=\"10215\">Apr\u00e8s la pand\u00e9mie, la lecture \u00e0 distance est l\u00e0 pour rester. Un flux de travail 100 % conforme \u00e0 l\u2019assurance qualit\u00e9 doit : <\/p>\n<ul data-start=\"10217\" data-end=\"10537\">\n<li data-start=\"10217\" data-end=\"10305\">\n<p data-start=\"10219\" data-end=\"10305\">Appliquer <strong data-start=\"10225\" data-end=\"10251\">les m\u00eames principes de conformit\u00e9 QA<\/strong> aux \u00e9crans de bureau \u00e0 domicile utilis\u00e9s pour le diagnostic primaire.<\/p>\n<\/li>\n<li data-start=\"10306\" data-end=\"10537\">\n<p data-start=\"10308\" data-end=\"10337\">Utilisez <strong data-start=\"10312\" data-end=\"10331\">des outils de contr\u00f4le qualit\u00e9 \u00e0 distance<\/strong> qui :<\/p>\n<ul data-start=\"10340\" data-end=\"10537\">\n<li data-start=\"10340\" data-end=\"10388\">\n<p data-start=\"10342\" data-end=\"10388\">Push les patrons TG18\/TG270 et les tests automatis\u00e9s<\/p>\n<\/li>\n<li data-start=\"10391\" data-end=\"10420\">\n<p data-start=\"10393\" data-end=\"10420\">Collectez les r\u00e9sultats de mani\u00e8re centralis\u00e9e<\/p>\n<\/li>\n<li data-start=\"10423\" data-end=\"10537\">\n<p data-start=\"10425\" data-end=\"10537\">Validez le DICOM GSDF et la luminance \u00e0 l\u2019aide de capteurs int\u00e9gr\u00e9s ou attachables.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3 data-start=\"10539\" data-end=\"10573\">6.2 Int\u00e9gration <strong data-start=\"557\" data-end=\"574\">de la conformit\u00e9 QA<\/strong> avec <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC1718393\/\" target=\"_blank\" rel=\"noopener\">PACS<\/a>\/RIS<\/h3>\n<p data-start=\"10575\" data-end=\"10590\">Lorsque possible :<\/p>\n<ul data-start=\"10592\" data-end=\"10802\">\n<li data-start=\"10592\" data-end=\"10699\">\n<p data-start=\"10594\" data-end=\"10699\">Stockez <strong data-start=\"10600\" data-end=\"10647\">les certificats QA et le dernier statut de r\u00e9ussite\/\u00e9chec<\/strong> \u00e0 c\u00f4t\u00e9 de chaque poste de travail dans la base de donn\u00e9es des actifs.<\/p>\n<\/li>\n<li data-start=\"10700\" data-end=\"10802\">\n<p data-start=\"10702\" data-end=\"10802\">En option, <strong data-start=\"10713\" data-end=\"10740\">bloquez les rapports primaires<\/strong> provenant d\u2019affichages hors sp\u00e9cifications jusqu\u2019\u00e0 ce que les probl\u00e8mes soient r\u00e9solus.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"10804\" data-end=\"10856\">6.3 Alignement sur les r\u00e9glementations locales et accr\u00e9ditation<\/h3>\n<ul data-start=\"10858\" data-end=\"11016\">\n<li data-start=\"10858\" data-end=\"11016\">\n<p data-start=\"10860\" data-end=\"10902\">Mappez votre flux de travail bas\u00e9 sur TG18\/TG270\/DIN \u00e0 :<\/p>\n<ul data-start=\"10905\" data-end=\"11016\">\n<li data-start=\"10905\" data-end=\"10946\">\n<p data-start=\"10907\" data-end=\"10946\">R\u00e9glementations nationales sur la s\u00e9curit\u00e9 radiologique<\/p>\n<\/li>\n<li data-start=\"10949\" data-end=\"10985\">\n<p data-start=\"10951\" data-end=\"10985\">Normes d\u2019accr\u00e9ditation hospitali\u00e8re<\/p>\n<\/li>\n<li data-start=\"10988\" data-end=\"11016\">\n<p data-start=\"10990\" data-end=\"11016\">Contrats de service fournisseurs<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p data-start=\"11018\" data-end=\"11115\">Si un auditeur pose la question, vous pouvez <strong data-start=\"11051\" data-end=\"11095\">montrer exactement comment chaque norme est mise en \u0153uvre<\/strong> dans votre QA de routine.<\/p>\n<h2 data-start=\"11122\" data-end=\"11176\">7. Exemple de liste de contr\u00f4le de conformit\u00e9 QA (pr\u00eat \u00e0 s\u2019adapter)<\/h2>\n<p data-start=\"11178\" data-end=\"11222\">Voici une liste simplifi\u00e9e <strong data-start=\"557\" data-end=\"574\">de contr\u00f4le de conformit\u00e9 QA <\/strong>que vous pouvez adapter :<\/p>\n<p data-start=\"11224\" data-end=\"11265\"><strong data-start=\"11224\" data-end=\"11265\">Pour chaque affichage de diagnostic primaire :<\/strong><\/p>\n<ul data-start=\"11267\" data-end=\"11795\">\n<li data-start=\"11267\" data-end=\"11328\">\n<p data-start=\"11269\" data-end=\"11328\">&#x2705; Saisie d\u2019inventaire avec mod\u00e8le, num\u00e9ro de s\u00e9rie, localisation, classe d\u2019utilisation<\/p>\n<\/li>\n<li data-start=\"11329\" data-end=\"11396\">\n<p data-start=\"11331\" data-end=\"11396\">&#x2705; Test d\u2019acceptation r\u00e9ussi (DIN 6868-157 \/ TG270) \u00e0 l\u2019installation<\/p>\n<\/li>\n<li data-start=\"11397\" data-end=\"11453\">\n<p data-start=\"11399\" data-end=\"11453\">&#x2705; V\u00e9rification visuelle quotidienne TG18-QC ou TG270-sQC document\u00e9e<\/p>\n<\/li>\n<li data-start=\"11454\" data-end=\"11616\">\n<p data-start=\"11456\" data-end=\"11513\">&#x2705; Tests quantitatifs mensuels\/trimestriels de surveillance m\u00e9dicale :<\/p>\n<ul data-start=\"11516\" data-end=\"11616\">\n<li data-start=\"11516\" data-end=\"11553\">\n<p data-start=\"11518\" data-end=\"11553\">Luminance \/ contraste (DICOM GSDF)<\/p>\n<\/li>\n<li data-start=\"11556\" data-end=\"11580\">\n<p data-start=\"11558\" data-end=\"11580\">Uniformit\u00e9 de la luminance<\/p>\n<\/li>\n<li data-start=\"11583\" data-end=\"11616\">\n<p data-start=\"11585\" data-end=\"11616\">Luminance ambiante et voilante<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"11617\" data-end=\"11684\">\n<p data-start=\"11619\" data-end=\"11684\">&#x2705; Test annuel d\u2019acceptation compl\u00e8te\/constance avec r\u00e9sultats document\u00e9s<\/p>\n<\/li>\n<li data-start=\"11685\" data-end=\"11734\">\n<p data-start=\"11687\" data-end=\"11734\">&#x2705; Plan d\u2019action corrective d\u00e9fini pour les d\u00e9faillances<\/p>\n<\/li>\n<li data-start=\"11735\" data-end=\"11795\">\n<p data-start=\"11737\" data-end=\"11795\">&#x2705; Donn\u00e9es QA stock\u00e9es pendant au moins la p\u00e9riode r\u00e9glementaire requise<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"11797\" data-end=\"11929\">Si vous pouvez cocher toutes ces cases avec assurance pour <strong data-start=\"11845\" data-end=\"11873\">chaque affichage de diagnostic<\/strong>, vous \u00eates extr\u00eamement proche d\u2019une <strong data-start=\"11901\" data-end=\"11928\">v\u00e9ritable conformit\u00e9 QA \u00e0 100 %.<\/strong><\/p>\n<h2 data-start=\"11936\" data-end=\"11991\">8. Pr\u00e9parer l\u2019avenir de votre programme <strong data-start=\"557\" data-end=\"574\">de conformit\u00e9 \u00e0 l\u2019assurance qualit\u00e9<\/strong> des \u00e9crans radiologiques<\/h2>\n<p data-start=\"11993\" data-end=\"12203\">Les normes continueront d\u2019\u00e9voluer \u2014 le DIN 6868-157 a \u00e9t\u00e9 de nouveau mis \u00e0 jour en 2022, et les normes techniques ACR\u2013AAPM pour les affichages d\u2019interpr\u00e9tation diagnostique continuent \u00e9galement d\u2019\u00eatre affin\u00e9es.<\/p>\n<p data-start=\"12205\" data-end=\"12238\">Pour rester en avance en 2026 et au-del\u00e0 :<\/p>\n<ul data-start=\"12240\" data-end=\"12717\">\n<li data-start=\"12240\" data-end=\"12364\">\n<p data-start=\"12242\" data-end=\"12364\">Choisissez <strong data-start=\"12249\" data-end=\"12275\">des outils et des plateformes QA<\/strong> qui sont activement maintenus et r\u00e9guli\u00e8rement mis \u00e0 jour pour refl\u00e9ter les r\u00e9visions TG270 et DIN.<\/p>\n<\/li>\n<li data-start=\"12365\" data-end=\"12468\">\n<p data-start=\"12367\" data-end=\"12468\">Participez \u00e0 des groupes <strong data-start=\"12382\" data-end=\"12424\">de travail de l\u2019AAPM, de l\u2019ESR ou des soci\u00e9t\u00e9s nationales de physique<\/strong> pour suivre les changements \u00e0 venir.<\/p>\n<\/li>\n<li data-start=\"12469\" data-end=\"12717\">\n<p data-start=\"12471\" data-end=\"12545\">R\u00e9visez et ajustez p\u00e9riodiquement vos proc\u00e9dures et seuils <strong data-start=\"557\" data-end=\"574\">de conformit\u00e9 QA<\/strong> en fonction de :<\/p>\n<ul data-start=\"12548\" data-end=\"12717\">\n<li data-start=\"12548\" data-end=\"12581\">\n<p data-start=\"12550\" data-end=\"12581\">Nouvelles preuves et publications<\/p>\n<\/li>\n<li data-start=\"12584\" data-end=\"12647\">\n<p data-start=\"12586\" data-end=\"12647\">Nouvelles technologies d\u2019affichage (haute luminosit\u00e9, HDR, OLED, etc.)<\/p>\n<\/li>\n<li data-start=\"12650\" data-end=\"12717\">\n<p data-start=\"12652\" data-end=\"12717\">Changements de flux de travail (superpositions IA, imagerie fusion, lecture \u00e0 distance).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2 data-start=\"12724\" data-end=\"12737\">Conclusion<\/h2>\n<p data-start=\"12739\" data-end=\"12978\">Un flux de travail de <strong data-start=\"557\" data-end=\"574\">conformit\u00e9 QA<\/strong> \u00e0 100 % pour les \u00e9crans de radiologie ne consiste pas \u00e0 faire plus de tests au hasard. Il s\u2019agit de construire un <strong data-start=\"12852\" data-end=\"12918\">syst\u00e8me structur\u00e9, align\u00e9 sur les normes, automatis\u00e9 et auditable<\/strong> , ancr\u00e9 dans <strong data-start=\"12931\" data-end=\"12944\">AAPM TG18<\/strong>, <strong data-start=\"12946\" data-end=\"12955\">TG270<\/strong> et <strong data-start=\"12961\" data-end=\"12977\">DIN 6868-157<\/strong>. <\/p>\n<p data-start=\"12980\" data-end=\"12983\">Par :<\/p>\n<ul data-start=\"12985\" data-end=\"13196\">\n<li data-start=\"12985\" data-end=\"13014\">\n<p data-start=\"12987\" data-end=\"13014\">Classifier vos affichages<\/p>\n<\/li>\n<li data-start=\"13015\" data-end=\"13053\">\n<p data-start=\"13017\" data-end=\"13053\">D\u00e9finition des plannings de tests bas\u00e9s sur le risque<\/p>\n<\/li>\n<li data-start=\"13054\" data-end=\"13107\">\n<p data-start=\"13056\" data-end=\"13107\">Standardisation des m\u00e9thodes <strong data-start=\"13070\" data-end=\"13097\">de test pour moniteurs m\u00e9dicaux<\/strong><\/p>\n<\/li>\n<li data-start=\"13108\" data-end=\"13151\">\n<p data-start=\"13110\" data-end=\"13151\">Automatisation de la planification et de la documentation<\/p>\n<\/li>\n<li data-start=\"13152\" data-end=\"13196\">\n<p data-start=\"13154\" data-end=\"13196\">Apprendre continuellement \u00e0 partir de ses propres donn\u00e9es<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"13198\" data-end=\"13374\">\u2026 Vous pouvez vous assurer que chaque radiologue lise sur un <strong data-start=\"13243\" data-end=\"13266\">\u00e9cran fiable<\/strong>, que chaque patient b\u00e9n\u00e9ficie d\u2019une qualit\u00e9 d\u2019image correcte, et que votre service soit pr\u00eat pour <strong data-start=\"13340\" data-end=\"13373\">2026 et ce qui viendra apr\u00e8s<\/strong>.<\/p>\n<p data-start=\"6325\" data-end=\"6550\">Dans un monde o\u00f9 chaque pr\u00e9cision Pixel compte, <strong data-start=\"6363\" data-end=\"6469\">PerfectLum by QUBYX prouve que l\u2019innovation peut offrir une pr\u00e9cision clinique sans compromis financier<\/strong>. Ce n\u2019est pas seulement de la calibration \u2014 <strong data-start=\"6502\" data-end=\"6547\">c\u2019est la d\u00e9mocratisation de l\u2019imagerie diagnostique<\/strong>. <\/p>\n<p data-start=\"6325\" data-end=\"6550\">Pour garantir <strong data-start=\"1343\" data-end=\"1373\">l\u2019assurance qualit\u00e9 de l\u2019affichage m\u00e9dical <\/strong>avec pr\u00e9cision tout en r\u00e9duisant les co\u00fbts r\u00e9currents du mat\u00e9riel propri\u00e9taire, la r\u00e9ponse est claire : passer d\u00e8s aujourd\u2019hui \u00e0 une <mark>plateforme logicielle d\u2019\u00e9talonnage <\/mark>avec <a href=\"https:\/\/qubyx.com\/qubyx-os-tools\/\"><b>QUBYX OS Tools<\/b><\/a> (gratuit) et <a href=\"https:\/\/qubyx.com\/products-perfectlum-4\/\"><b>PerfectLum<\/b><\/a> . Maintenant, vous payez facilement moins cher pour la radiologie. <\/p>\n<p data-start=\"7431\" data-end=\"7573\"><strong>\u00c9tiquettes:<\/strong><\/p>\n<p data-start=\"7431\" data-end=\"7573\">Conformit\u00e9 QA, QA d\u2019affichage radiologique, AAPM TG18, AAPM TG270, DIN 6868-157, tests de moniteurs m\u00e9dicaux, DICOM GSDF, \u00e9talonnage des affichages diagnostiques, flux de travail QA en radiologie<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Comment construire un flux de travail 100 % conforme au contr\u00f4le qualit\u00e9 des \u00e9crans de radiologie en 2026 et au-del\u00e0 [&hellip;]<\/p>\n","protected":false},"author":770,"featured_media":11836,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1250,1252,1251,1292,1323],"tags":[1296,1555,1643,1644,1325,1297,1646,1642,1645],"class_list":["post-11835","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actualites","category-logiciel-qubyx","category-perfectlum","category-qubyx-os","category-qubyxviewer","tag-aapm-tg18","tag-aapm-tg270","tag-calibration-de-laffichage-de-diagnostic","tag-conformite-a-lassurance-qualite","tag-dicom-gsdf","tag-din-6868-157","tag-flux-de-travail-qa-en-radiologie","tag-qa-des-affichages-de-radiologie","tag-tests-de-moniteurs-medicaux"],"acf":[],"_links":{"self":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts\/11835","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/users\/770"}],"replies":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/comments?post=11835"}],"version-history":[{"count":0,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/posts\/11835\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/media\/11836"}],"wp:attachment":[{"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/media?parent=11835"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/categories?post=11835"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qubyx.com\/fr\/wp-json\/wp\/v2\/tags?post=11835"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}